5 - 2 5 - 2
MELSEC-Q
5 UTILITY PACKAGE (GX Configurator-TI)
Function Description
Reference
section
Monitor/test
(2) Offset/Gain Setting
Section 5.6
• Mode Switching Setting
• Mode Switching Setting Status
• CH Setting Range
• CH Offset Temperature Setting Value
• CH Offset Setting Request
• CH Gain Temperature Setting Value
• CH Gain Setting Request
• CH Measured Temperature Value (16bit)
• CH Measured Temperature Value (32bit)
• User Range Write Request
• Offset/gain Setting Mode Status Flag
(3) X/Y Monitor/Test
• Xn0: Module Ready
• Xn1: CH1 Offset/Gain Setting Status Signal
• Xn2: CH2 Offset/Gain Setting Status Signal
• Xn3: CH3 Offset/Gain Setting Status Signal
• Xn4: CH4 Offset/Gain Setting Status Signal
• Xn9: Operating Condition Setting Completion Signal
• XnA: Offset/gain Setting Mode Status Flag
• XnC: Disconnection Detection Signal
• XnD: Warning Output Signal
• XnE: Conversion Completion Flag
• XnF: Error Flag
• Yn1: CH1 Offset Setting Request
• Yn2: CH1 Gain Setting Request
• Yn3: CH2 Offset Setting Request
• Yn4: CH2 Gain Setting Request
• Yn5: CH3 Offset Setting Request
• Yn6: CH3 Gain Setting Request
• Yn7: CH4 Offset Setting Request
• Yn8: CH4 Gain Setting Request
• Yn9: Operating Condition Setting Request
• YnA: User Range Write Request
• YnF: Error Clear Request
(4) OMC Refresh Data
• 3/4-wire type CH Factory default offset/gain input
value
• 3/4-wire type CH User range settings offset/gain
value
• 3/4-wire type CH User range settings
offset/gain resistance value
• OMC refresh data read request
• OMC refresh data write request
POINT
1 For the initial setting and auto refresh setting, memory capacity of Max. 76
bytes per module is required for the Intelligent function module parameters.
2 Verify the input range displayed on the utility package screen and then enter
values.
If a value outside the input range is set, an error will not be identified on the
utility package but detected during module operation.
In such a case, check the error code and set an appropriate value.
3 Monitoring only is available. The tests are not executable.
5