6 - 2 6 - 2
MELSEC-Q
6 PROGRAMMING
6.1.1 Program example used when utility package is used
(1) Operation of utility package
(a) Initial setting (refer to Section 5.4)
Set Sampling processing for CH1, averaging processing of every 500 counts
for CH2 and averaging processing in a cycle of 1000ms for CH3.
(b) Auto refresh settings (refer to Section 5.5)
Set devices to store CH1 to CH3 Measured temperature values, error code,
and disconnection detection flag.
(c) Write of intelligent function module parameters (refer to Section 5.3.3)
Write the intelligent function module parameters to the CPU module. Perform
this operation on the parameter setting unit selection screen.