8 - 5 8 - 5
8 TROUBLESHOOTING
MELSEC-Q
8.2.10 Checking the Q64RD/Q64RD-G status using GX Developer system monitor
When the Q64RD/Q64RD-G detailed information is selected in GX Developer system
monitor, an error code and LED status can be checked.
(1) Operating GX Developer
[Diagnostics] [System monitor] "Select Q64RD/Q64RD-G "
Module Detailed Information
(2) Module's Detailed Information
(a) Checking the function version and product information
The function version and product information of the Q64RD/Q64RD-G is
displayed in the product information field.
(b) Checking the error code
The error code stored in buffer memory address 19 (Un
\
G19) of the
Q64RD/Q64RD-G is displayed in the Present Error field.
(When the Error History button is pressed, the contents displayed in the
Present Error field are displayed in the No. 1 field.)