3 - 18 3 - 18
3 SPECIFICATIONS
MELSEC-Q
Addresses
Description
R/W
1
Reference
section
Hex. Dec.
76
H
118
CH1 offset temperature set value
(L)
(H)
R/W
2
Section 3.4.20
77
H
119
78
H
120
CH1 gain temperature set value
(L)
(H)
R/W
2
79
H
121
7A
H
122
CH2 offset temperature set value
(L)
(H)
R/W
2
7B
H
123
7C
H
124
CH2 gain temperature set value
(L)
(H)
R/W
2
7D
H
125
7E
H
126
CH3 offset temperature set value
(L)
(H)
R/W
2
7F
H
127
80
H
128
CH3 gain temperature set value
(L)
(H)
R/W
2
81
H
129
82
H
130
CH4 offset temperature set value
(L)
(H)
R/W
2
83
H
131
84
H
132
CH4 gain temperature set value
(L)
(H)
R/W
2
85
H
133
86
H
134
Extended averaging processing specification
R/W
2
Section 3.4.21
87
H
135
System area
— —
to to
93
H
147
94
H
148
Conversion setting for disconnection detection
R/W
2
Section 3.4.22
95
H
149
System area
— —
96
H
150
CH1 Conversion setting value for disconnection
(L)
detection (H)
R/W
2
Section 3.4.23
97
H
151
98
H
152
CH2 Conversion setting value for disconnection
(L)
detection (H)
R/W
2
99
H
153
9A
H
154
CH3 Conversion setting value for disconnection
(L)
detection (H)
R/W
2
9B
H
155
9C
H
156
CH4 Conversion setting value for disconnection
(L)
detection (H)
R/W
2
9D
H
157
9E
H
158
Mode switching setting
R/W Section
3.4.24
9F
H
159
A0
H
160
3-wire type CH1 Factory default offset value
3
R/W
Section 3.4.25
A1
H
161
3-wire type CH1 Factory default offset value
3
R/W
A2
H
162
3-wire type CH1 Factory default gain value
3
R/W
A3
H
163
3-wire type CH1 Factory default gain value
3
R/W
A4
H
164
3-wire type CH1 User range setting offset value
3
R/W
A5
H
165
3-wire type CH1 User range setting offset value
3
R/W
A6
H
166
3-wire type CH1 User range settings gain value
3
R/W
A7
H
167
3-wire type CH1 User range settings gain value
3
R/W
A8
H
168
3-wire type CH1 User range settings offset
(L)
3
resistance value
(H)
R/W
A9
H
169
AA
H
170
3-wire type CH1 User range settings gain
(L)
3
resistance value
(H)
R/W
AB
H
171
AC
H
172
4-wire type CH1 Factory default offset value
3
R/W
AD
H
173
4-wire type CH1 Factory default offset value
3
R/W
AE
H
174
4-wire type CH1 Factory default gain value
3
R/W
AF
H
175
4-wire type CH1 Factory default gain value
3
R/W
B0
H
176
4-wire type CH1 User range setting offset value
3
R/W
B1
H
177
4-wire type CH1 User range setting offset value
3
R/W
B2
H
178
4-wire type CH1 User range settings gain value
3
R/W
B3
H
179
4-wire type CH1 User range settings gain value
3
R/W
B4
H
180
4-wire type CH1 User range settings offset
(L)
3
resistance value
(H)
R/W
B5
H
181
B6
H
182
4-wire type CH1 User range settings gain
(L)
3
resistance value
(H)
R/W
B7
H
183
B8
H
184
3-wire type CH2 Factory default offset value
3
R/W
B9
H
185
3-wire type CH2 Factory default offset value
3
R/W