Appendix 4 Link Special Register (SW) List
SW000B
Number of resends
(RIRD/RIWT)
If the instruction is not completed within the monitoring time specified by the Arrival
monitoring time (RIRD/RIWT) (SW0009), this specifies the number of times that the
instruction is resent.
• 0: Not resent (default value)
• 1 to 7: 1 to 7 times
If a value outside the above settings is made, the instruction is resent 7 times.
SW0010 to
SW0017
Reserved station
function disable/
temporary error
invalid station setting
Specifies the slave stations where reserved station function disable or temporary error
invalid station setting/cancel is performed.
• 0: Not specified
• 1: Specified
(Conditions)
• Some stations cannot be specified as reserved station function disable or
temporary error invalid station setting/cancel. (
function enable, Page 135 Enable/Disable ignore station errors)
• Stations higher than the maximum station number are ignored.
SW001A
Number of resends
(REMFR/REMTO)
Specifies the number of resends for the REMFR/REMTO instruction.
• 0: 0 times (default)
• Outside the above: Number of times that is set
(Conditions)
This is enabled when the Baton pass status (own station) (SB0047) is OFF.
SW001B
Response wait timer
(REMFR/REMTO)
Specifies the response wait time for the REMFR/REMTO instruction.
• 0: 10 seconds (default)
• Outside the above: Number of seconds that is set
(Conditions)
This is enabled when the Baton pass status (own station) (SB0047) is OFF.
SW0030
Send/receive
instruction (1)
processing result
Stores the processing results of the link dedicated instruction that used the own
station's channel 1.
• 0: Normal completion
• 1 or higher: Abnormal completion (
SW0031
Send/receive
instruction (2)
processing result
Stores the processing results of the link dedicated instruction that used the own
station's channel 2.
• 0: Normal completion
• 1 or higher: Abnormal completion (
SW0040
Network number
Stores the network number of own station.
• Range: 1 to 239
SW0042
Station number
Stores the station number of own station.
• Range: 1 to 120 (master station: 125)
SW0043
Mode status
Stores the mode of own station.
• 0: Online (Normal Mode) (Local station: Online)
• 1: Online (High Speed Mode)
• 2: Offline
• 6: Loop test
• 7: Self-loopback test
• 9: Hardware test
SW0046
Module type
Stores the own station's hardware status.
Number
Name
Description
Availability
Master
station
Local
station
SW0010
SW0011
SW0012
SW0013
SW0014
SW0015
SW0016
SW0017
b15 b14 b13 b12 b11 b10 b9 b8
b7 b6 b5 b4 b3 b2 b1 b0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
Each number in the table represents station No.
SW0046
b15
b2
b0
b1
0
0
Module type
00
:
Module
01
:
Board
10
:
HMI
to
to
Summary of Contents for MELSEC Q80BD-J71GF11-T2
Page 2: ......
Page 6: ...4 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Page 118: ...116 12 MONITORING MEMO ...
Page 140: ...138 14 MELSEC DATA LINK LIBRARY MEMO ...
Page 142: ...140 15 PROGRAMMING 15 1 Precautions on Programming MEMO ...
Page 243: ...241 I U Utility 83 ...
Page 247: ......