Appendix 3 Link Special Relay (SB) List
SB00B1
Data link status
(master station)
Stores the cyclic transmission status for the master station.
• OFF: Normal
• ON: Error
(Conditions)
This is enabled when the Baton pass status (own station) (SB0047) is OFF.
SB00B8
Network connection
status (each station)
Stores if any network connection station is found.
• OFF: No network connection station
• ON: Network connection station found
If a network connection station is found, the status of each station can be checked
using Network connection status (SW00B8 to SW00BF).
Depending on the timing of the link refresh, the update of Network connection status
(SW00B8 to SW00BF) may be offset by one sequence scan.
SB00C0
Reserved station
specification
Stores if there are any reserved stations.
• OFF: No reserved stations
• ON: Reserved stations found
If a reserved station is found, the status of each station can be checked by Reserved
station specification (SW00C0 to SW00C7).
Depending on the timing of the link refresh, the update of Reserved station
specification (SW00C0 to SW00C7) may be offset by one sequence scan.
(Conditions)
This is enabled when the Baton pass status (own station) (SB0047) is OFF.
SB00D0
Error invalid station
setting
Stores if there are any error invalid stations.
• OFF: No error invalid stations
• ON: Error invalid station found
If an error invalid station is found, the status of each station can be checked by Error
invalid station setting (SW00D0 to SW00D7).
Depending on the timing of the link refresh, the update of Error invalid station setting
(SW00D0 to SW00D7) may be offset by one sequence scan.
(Conditions)
This is enabled when the Baton pass status (own station) (SB0047) is OFF.
SB00E0
Temporary error
invalid station status
Stores if there are any temporary error invalid stations.
• OFF: No temporary error invalid stations
• ON: Temporary error invalid station found
If a temporary error invalid station is found, the status of each station can be checked
by Temporary error invalid station setting (SW00E0 to SW00E7).
Depending on the timing of the link refresh, the update of Temporary error invalid
station setting (SW00E0 to SW00E7) may be offset by one sequence scan.
(Conditions)
This is enabled when the Baton pass status (own station) (SB0047) is OFF.
SB00E8
Station type match
status (each station)
Stores the station type match status of each station.
• OFF: Station type match in all stations
• ON: Station type mismatch station found
If a station type mismatch station is found, the status of each station can be checked
using Station type match status (SW00E8 to SW00EF).
Depending on the timing of the link refresh, the update of Station type match status
(SW00E8 to SW00EF) may be offset by one sequence scan.
SB00F0
CPU RUN status
(each station)
Stores the RUN status of each station's CPU module.
• OFF: All stations are in RUN or STEP-RUN status
• ON: Station in STOP or PAUSE status found
If a station in STOP or PAUSE status is found, the status of each station can be
checked by the CPU RUN status (each station) (SW00F0 to SW00F7).
Depending on the timing of the link refresh, the update of CPU RUN status (each
station) (SW00F0 to SW00F7) may be offset by one sequence scan.
(Conditions)
This is enabled when the Baton pass status (own station) (SB0047) is OFF.
SB00F1
CPU RUN status
(master station)
Stores the RUN status of the master station's CPU module.
• OFF: RUN or STEP-RUN status
• ON: STOP or PAUSE status
(Conditions)
This is enabled when the Baton pass status (own station) (SB0047) is OFF.
Number
Name
Description
Availability
Master
station
Local
station
Summary of Contents for MELSEC Q80BD-J71GF11-T2
Page 2: ......
Page 6: ...4 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Page 118: ...116 12 MONITORING MEMO ...
Page 140: ...138 14 MELSEC DATA LINK LIBRARY MEMO ...
Page 142: ...140 15 PROGRAMMING 15 1 Precautions on Programming MEMO ...
Page 243: ...241 I U Utility 83 ...
Page 247: ......