28
2 SYSTEM CONFIGURATION
2.2 CC-Link IE Field Network Configuration
Data link error in all stations when starting a personal computer
Errors occur in all stations when a personal computer is started.
This is because the line between P1 and P2 of CC-Link IE Field Network board is disconnected under the following
conditions.
• The power of the personal computer is turned OFF. (The line becomes in a conduction state when the power is turned ON.)
• A reconnection is in progress when starting a board driver.
As a result, the following reconnection occurs and causes an error in all station.
• A reconnection of CC-Link IE Field Network board installed in a personal computer.
• A reconnection of station which is located beyond the CC-Link IE Field Network board from the point of the master station.
If multiple boards are installed in a single personal computer, this symptom occurs for the same number of times as the
number of installed boards.
Connected station numbers
Connected station numbers should not be duplicated. Data link may be stopped when the station number is duplicated.
Turn-ON order
To avoid incorrect input from slave stations, turn ON slave stations first and then the master station.
Duplication
Station No.0
Station No.1
Station No.1
Station No.2
(Data link may stop.)
Summary of Contents for MELSEC Q80BD-J71GF11-T2
Page 2: ......
Page 6: ...4 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Page 118: ...116 12 MONITORING MEMO ...
Page 140: ...138 14 MELSEC DATA LINK LIBRARY MEMO ...
Page 142: ...140 15 PROGRAMMING 15 1 Precautions on Programming MEMO ...
Page 243: ...241 I U Utility 83 ...
Page 247: ......