CHAPTER 1 SCREEN OPERATIONS
2. Monitor (Operation) Screens
I
– 104
2.10.2 Control parameter 1 details
The system common control parameters are displayed and set on this screen.
For parameters indicated with a "
∗
" in the table, turn the NC power OFF after setting. The setting is
validated after the power is turned ON again.
# Item
Setting
Details
ON
The inch command mode the initial state when the power is
turned ON.
(The parameters, offset amount, etc., all are inch settings.)
310001 Initial inch
∗
OFF
The metric command mode the initial state when the power is
turned ON. (The input setting unit is also metric.)
310002 %
rewind
(search)
ON
During tape search, the tape is rewound and stopped when the
program is read to program end (%), and the designated block
is not found.
OFF
During tape search, the tape is not rewound when the program
is read to program end (%), and the designated block is not
found. Instead the program is stopped at that position.
310003 Edit lock B
ON
Editing of the label No. 8000 to 9999 machining program is
locked.
OFF
Editing of the label No. 8000 to 9999 machining program is
enabled.
310004 Com-var
RST
clear
ON
After resetting, #100 to #149 are cleared to "blank" when there
are 100 common variable sets, and #100 to #199 when there
are 200 or 300 common variable sets.
OFF
The common variables are held when reset.
310005 Com-var
PWR-ON clear
ON
When the power is turned ON, #100 to #149 are cleared to
"blank" when there are 100 common variable sets, and #100 to
#199 when there are 200 or 300 common variable sets.
OFF
The common variables are held when the power is turned ON
or OFF.
Downloaded from
Summary of Contents for MELDAS 600M Series
Page 15: ...CHAPTER 1 SCREEN OPERATIONS Downloaded from ManualsNet com search engine ...
Page 333: ...CHAPTER 2 MACHINE OPERATIONS Downloaded from ManualsNet com search engine ...
Page 386: ...CHAPTER 3 MAINTENANCE Downloaded from ManualsNet com search engine ...
Page 442: ...CHAPTER 4 APPENDICES Downloaded from ManualsNet com search engine ...