CHAPTER 4 APPENDICES
Appendix 3. Alarm Messages
IV
– 25
3.2 Servo errors (SV
)
The following markings show the appropriate method for canceling the error.
AR : Cancel by turning the servo drive unit power OFF, then ON again.
PR : Cancel by turning the NC power OFF, then ON again.
NR : Cancel by resetting the NC.
(Note)
The "SV0050 Overload 1" alarm cannot be canceled unless the reset level or less
has been reached. Refer to the MELDAS AC Servo and Spindle Specifications
Manual (BNP-B3759) for details.
−
: The normal status will automatically return when the warning state is canceled.
No. Abbrev.
Message
Details
Cancel-
lation
method
SV0010 UV
Under voltage
The PN bus voltage is 200V or less.
PR
SV0011 ASE
Axis selection error
The setting of the axis setting rotary switches on
the 2-axis integrated drive unit is illegal.
AR
SV0012 ME1
Memory error 1
The memory IC (SRAM or FLROM) check sum
is illegal.
AR
SV0013 SWE
S/W processing error
S/W data processing did not end within the
specified time. (Including peripheral G/A errors.)
PR
SV0016 RD1
Magnetic pole position
detect err 1
The difference input for one of the magnetic pole
position detection signal U, V or W phases of the
OHE-type detector has become "H" or "L".
PR
SV0017 ADE
AD converter error
The AD convertor for current detection did not
work correctly at initialization.
PR
SV0018 WAT
Initial communication error Correct communication of the absolute position
or magnetic pole position data is not possible
with the OHA-type detector or serial pulse
encoder.
PR
SV001A WATS Communication error
(SUB)
Initial communication with the detector was not
possible with the system that uses the
OHA25K-ET machine end detector.
PR
SV001B SCPUS CPU error (SUB)
An error was detected in the data stored in the
EEPROM with the high-speed serial detector
connected to the machine end.
PR
SV001C SLEDS LED error (SUB)
LED deterioration was detected with the
high-speed serial detector connected to the
machine end.
PR
SV001D SDATS Data error (SUB)
An error was detected in the position per rotation
with the high-speed serial detector connected to
the machine end.
PR
SV001E SOHE
Thermal error (SUB)
The thermal protector built into the detector
activated with the high-speed serial detector
connected to the machine end.
PR
SV001F STRES Communication
error
(SUB)
Communication with the detector was cut off with
the high-speed serial detector connected to the
machine end.
PR
Downloaded from
Summary of Contents for MELDAS 600M Series
Page 15: ...CHAPTER 1 SCREEN OPERATIONS Downloaded from ManualsNet com search engine ...
Page 333: ...CHAPTER 2 MACHINE OPERATIONS Downloaded from ManualsNet com search engine ...
Page 386: ...CHAPTER 3 MAINTENANCE Downloaded from ManualsNet com search engine ...
Page 442: ...CHAPTER 4 APPENDICES Downloaded from ManualsNet com search engine ...