CHAPTER 2 MACHINE OPERATIONS
6. Operation Switch Functions and Other Functions
II
– 33
(2) Operation during manual/automatic simultaneous operation
(a) The manual operation and automatic operation feedrates are independent. The acceleration/
deceleration mode (rapid traverse/cutting feed) and time constants are also independent.
(b) The rapid traverse override is valid for both automatic operation and manual operation. The
cutting feed override and 2nd cutting feed override are valid only for automatic operation.
However, these will also be valid during manual operation if the manual override valid signal is
ON. Override cancel is valid only for automatic operation.
(c) Manual interlock is valid for the manual/automatic simultaneous valid axis, and automatic
interlock is valid for the axis in automatic operation.
(d) Manual machine lock is valid for the manual/automatic simultaneous valid axis, and automatic
machine lock is valid for the axis in automatic operation.
(e) The signals in cutting feed and in rapid traverse will follow the automatic operation movement
mode.
(f) Movement of the manual/automatic simultaneous valid axis will not stop with the single block
stop or feed hold stop.
(g) If the manual/automatic simultaneous valid axis reaches the stored stroke limit or stroke limit,
the axis moving in automatic operation will also stop immediately, and the feed hold state will
be entered. In this case, automatic operation can be restarted by canceling the stored stroke
limit or stroke limit with manual operation.
(h) Even if the automatic operation handle interrupt option is added and the handle mode is
selected for the manual operation mode, the manual/automatic simultaneous function will be
the priority for the axis for which the "manual/automatic simultaneous valid" signal is ON.
(i) The speed display indicates the following speeds according to the actual feedrate display
parameter (base system #120040).
For actual feedrate display 1
For actual feedrate display 0
Manual/automatic
simultaneous
operation
Composite manual and
automatic speeds
(The actual feedrates are
independent.)
Automatic F command speed
priority
(Manual command speed when
there is no axis moving with
automatic operation)
Only manual operation Manual actual feedrate
Manual command speed
Only automatic
operation
Automatic actual feedrate
Automatic F command speed
Downloaded from
Summary of Contents for MELDAS 600M Series
Page 15: ...CHAPTER 1 SCREEN OPERATIONS Downloaded from ManualsNet com search engine ...
Page 333: ...CHAPTER 2 MACHINE OPERATIONS Downloaded from ManualsNet com search engine ...
Page 386: ...CHAPTER 3 MAINTENANCE Downloaded from ManualsNet com search engine ...
Page 442: ...CHAPTER 4 APPENDICES Downloaded from ManualsNet com search engine ...