Ventilation mode
Display
AUTO
HEAT EX.
BY-PASS
Display will change
automatically depending
on environmental
circumstances.
* If either “HEAT EX.” or “BY-PASS” is selected and
1
and
2
blink alternately
at an interval of five seconds in the dot display, it is recommended to select
“AUTO”. (The display blinks for a maximum of 10 minutes.)
Using the Timer
This section explains how to set and use the timer. You can use Function Selection of remote controller to select which of three types of timer to use:
1
Weekly timer,
2
Simple timer
.
For information about how to set the Function Selection of remote controller, refer to section “Installation Manual”, item [5]–3 (2).
Note:
• Weekly Timer and Simple Timer cannot be used at the same time.
• If two remote controllers are connected to one machine or group and the timer is used, set the timer only in one remote controller, and set “Timer disabled” in the other. The
system will not operate correctly if two different timers are set in the two remote controllers.
1
Using the Weekly Timer
■
The weekly timer can be used to set up to eight operations for each day of the week.
• Each operation may consist of any of the following: ON/OFF time together with fan speed setting, or ON/OFF time only, or fan speed setting only.
• When the current time reaches a time set at this timer, the Lossnay unit carries out the action set by the timer.
■
Time setting resolution for this timer is 1 minute.
Examples
Note:
*1. The weekly timer will not operate when any of the following conditions is in effect.
The timer feature is off; the user is in the process of setting a function; the user is in the process of setting the timer; the user is in the process of setting the current day
of the week or time; the system is under central control. (Specifically, the system will not carry out operations (unit on, unit off setting) that are prohibited during these
conditions.)
*2. The Weekly timer may be used if the clock use setting is ON (use clock) in Function Selection.
8:00 9:00
12:00
13:00
17:00
20:00
22:00
7
Low
1
High
2
Low
3
High
4
Low
5
Extra
6
Stop
Low
Pressing Function Selector button
4
2
3
1
Day Setting
Operation No.
Setup Matrix
Op No.
Sunday
Monday
...
Saturday
No. 1
• 9:00
• ON
• High
No. 2
• 10:00
• OFF
• 10:00
• OFF
• 10:00
• OFF
• 10:00
• OFF
...
No. 8
Note:
By setting the day to “Sun Mon Tue Wed Thu Fri Sat”,you can set the same
operation to be carried out at the same time every day.
(Example: Operation 2 above, which is the same for all days of the week.)
<Operation 1 settings
for Sunday>
Start the Lossnay
unit at 9:00, with fan
speed set to High.
<Operation 2 settings
for every day>
Turn off the Lossnay
unit at 10:00.
<How to Set the Weekly Timer>
1. Be sure that you are at a standard control screen, and that the weekly timer
indicator
1
is shown in the display
.
2. Press the [
MENU] button
B
, so that the“TIMER SET” appears on the screen
(at
2
). (Note that each press of the button toggles the display between“TIMER
SET” and “TIMER MONITOR”.)
3. Press the [
ON/OFF (DAY)] button
9
to set the day. Each press advances the
display at
3
to the next setting, in the following sequence: “SUN MON TUE WED
THU FRI SAT”
“SUN”
...
“FRI”
“SAT”
“SUN MON TUE WED THU
FRI SAT”...
4. Press the
or
OPERATION buttons (
7
or
8
) as necessary to select the
appropriate operation number (1 to 8)
4
.
* Your inputs at Steps 3 and 4 will select one of the cells from the matrix
illustrated below.
(The remote controller display at left shows how the display would appear when
setting Operation 1 for Sunday to the values indicated below.)
<How to set the Weekly Timer>
5. Press the appropriate [
CLOCK] button
A
as necessary to set the desired time (at
5
).
* As you hold the button down, the time first increments in minute intervals, then in
10-minute intervals, and then in 1-hour intervals.
6. Press the [
ON/OFF] button
1
to select the desired operation (ON or OFF), at
6
.
* Each press changes the next setting, in the following sequence: No display (no setting)
“ON” “OFF”
Note:
The timer will not function when not displayed.
7. Press the Fan Speed Adjustment button
3
to set the fan speed (at
7
).
* Each press changes the setting, in the following sequence: No display (no setting)
Extra High High Low Extra Low No display.
Note:
When not displayed, the system will operate at the currently set fan speed (other than Extra
Low)
For the Lossnay models without extra low fan speed, the speed will not be displayed.
8. To clear the currently set values for the selected operation, press and quickly release the
CLEAR button
0
once.
* The displayed time setting will change to “—:—”, and the On/Off and fan speed settings
will all disappear. (To clear all weekly timer settings at once, hold down the CLEAR
button
0
for two seconds or more. The display will begin flashing, indicating that all
settings have been cleared.)
Shows the fan speed setting
6
7
5
Shows the time setting
Shows the selected operation (ON or OFF)