© Mitsubishi Electric Corporation
58
3-3-4 DXL-NL series illumination
(
LED)
control signal output
(This cable is not included in the CIS product)
2) Fix CIS connectors and the cable by screws
CIS has locknut D20418-J3R (JAE) (M2.6, female).
Use M2.6 screw, M2.5 screw, M2.6 type JAE Lock screw,
etc., which are applicable to fasten cable connectors.
Recommended tightening torque is 16 - 20 N*cm.
【Remarks】
1) Do not screw with higher torque than recommended.
Otherwise, locknut on CIS may be loosened or removed, when
you remove screws.
2) CIS does not support hot-swap.
Make sure to power off CIS before connecting / removing
cables. If the cables are connected / removed while
powered on, it may cause failure on CIS.
3-3 Connections
Non-illumination type CIS (DXL-NL series) outputs a
trigger signal from connector L1, that is used to synchronize
the output of this product with an external illumination. When
using this trigger signal for the external illumination control,
connect
⑦
External illumination control cable to the
connector L1.
TM-XJ959A
Summary of Contents for KD Series
Page 3: ... Mitsubishi Electric Corporation 3 Chapter 1 Notice TM XJ959A ...
Page 17: ... Mitsubishi Electric Corporation 17 Chapter 2 Overview TM XJ959A ...
Page 40: ... Mitsubishi Electric Corporation 40 Chapter 3 Installation TM XJ959A ...
Page 59: ... Mitsubishi Electric Corporation 59 Chapter 4 How to control CIS TM XJ959A ...
Page 64: ... Mitsubishi Electric Corporation 64 Chapter 5 Getting started TM XJ959A ...