© Mitsubishi Electric Corporation
3-3-3
Camera Link®
connectors
(This cable is not included in the CIS product)
1
)
Connect Camera Link® cable to
D1-D8(for L4/L5) or D1-D12(for L6)
.
* CIS has Mini-Camera Link® connectors 12226-1150-00PL(3M).
57
【
Remarks
】
1)When you use several Grabber boards, the external sync signal
can be provided only through Master Communication port
(L4/L5:D1,L6:D5). Also communication control for the main functions
can be set only through Master Communication port.
(L4/L5:D1,L6:D5) Remark when changing Grabber board settings.
2)CIS does not support PoCL. Set the Frame Grabber board settings
NOT to 12V power over the Camera Link® cable.
3)Pin assignment of the Camera Link® connectors are conformed to
Camera Link® standard.
4)
Recommended screwing torque is 12 N*cm.
3-3 Connections
【
L4/L5
】
【
L6
】
Type
No.
Model
L4
L5
L6
Camera Link® Connectors
*
◎
: Master Communication port
D1
◎
◎
○
D2
○
○
○
D3
○
○
○
D4
○
○
○
D5
○
○
◎
D6
○
○
○
D7
○
○
○
D8
○
○
○
D9
×
×
○
D10
×
×
○
D11
×
×
○
D12
×
×
○
Camera Link® is a registered trademark of AIA (Automated Imaging Association).