© Mitsubishi Electric Corporation
92
Address
Register name
R/W
Parameter
Data
Function
Initial
7004h BaudRateSelect
R/W
0 to 2
Switch baud rate of UART communication in Camera Link®
0: 9.6kbps, 1: 19.2kbps, 2: 115.2kbps
0
7008h ContTimeOut
R/W
0 to 65535
Setting time of time out for UART communication in Camera Link®
0:Disable, 1:0.2seconds afterwards every 0.2seconds
150
7010h LedSelector
R/W
0 to 3
Illumination(
LED) control
0:OFF
1: Upper-stream Illumination(A) ON
2: Down-stream Illumination(B) ON
3: Both Upper-stream (A) and Down-stream (B) ON
3
7014h LedPulseDivision
R/W
0 to 3
Set
illumination(
LED) Pulse division
0:OFF, 1: 2 pulses, 2: 4 pulses, 3: 8 pulses
0
7018h LedPulseWidthA
R/W
0 to 65535 Upper-stream
illumination(
A) period or pulse width
450
701Ch LedPulseWidthB
R/W
0 to 65535 Down-stream
illumination(
B) period or pulse width
450
7020h LedEffectivePeriod
R/W
0 to 65535 Set
illumination(
LED) Effective Period
692
7030h ShutterEnable
R/W
0 or 1
Set Electric shutter On/Off
0:OFF /1:ON
0
7034h ShutterEnd
R/W
0 to 32765 Set exposure end timing
130
7038h ShutterWidth_R
R/W
1 to 32764 Set Red exposure period
1
703Ch ShutterWidth_G
R/W
1 to 32764 Set Green exposure period
1
7040h ShutterWidth_B
R/W
1 to 32764 Set Blue exposure period
1
7050h DarkCorrectionEnable
R/W
0 or 1
Set Dark correction On/Off
0:OFF /1:ON
0
7054h DarkCorrectionExecute R/W
1
Generate Dark correction data
-
7070h WhiteCorrectionEnable R/W
0 or 1
Set White correction On/Off
0:OFF /1:ON
0
7074h WhiteTarget_R
R/W
0 to 4095
Set Red White Correction Target value
4000
7078h WhiteTarget_G
R/W
0 to 4095
Set Green White Correction Target value
4000
707Ch WhiteTarget_B
R/W
0 to 4095
Set Blue White Correction Target value
4000
Appendix A: Control register list
③
TM-XJ959A
Camera Link® is a trade mark registered by AIA
(
Automated Imaging Association).
Summary of Contents for KD Series
Page 3: ... Mitsubishi Electric Corporation 3 Chapter 1 Notice TM XJ959A ...
Page 17: ... Mitsubishi Electric Corporation 17 Chapter 2 Overview TM XJ959A ...
Page 40: ... Mitsubishi Electric Corporation 40 Chapter 3 Installation TM XJ959A ...
Page 59: ... Mitsubishi Electric Corporation 59 Chapter 4 How to control CIS TM XJ959A ...
Page 64: ... Mitsubishi Electric Corporation 64 Chapter 5 Getting started TM XJ959A ...