© Mitsubishi Electric Corporation
93
Address
Register name
R/W
Parameter
Data
Function
Initial
7080h WhiteCorrectionExecute
R/W
1
Generate White Correction data (Normal Trigger mode)
-
7084h
WhiteCorrectionExtra
Triger
R/W
0 or 1
Generate White Correction data (External Trigger mode)
0:END / 1:START
0
70A0h DegitalGainEnable
R/W
0 or 1
Set Degital Gain On/Off
0:OFF /1:ON
0
70A4h DegitalGain_R
R/W
-1024 to 3071
Set a value of Red PGA (0 to 4.0)
0
70A8h DegitalGain_G
R/W
-1024 to 3071 Set a value of Green PGA (0 to 4.0)
0
70ACh DegitalGain_B
R/W
-1024 to 3071 Set a value of Blue PGA (0 to 4.0)
0
70B0h ResolutionSetting
R/W
0 to 4
Set Resolution and Interpolation On/Off
0: 600dpi, Interpolation ON
1: 600dpi, Interpolation OFF
2: 300dpi mode
3: 200dpi mode
4: 150dpi mode
※
Interpolation is not supported on 300,200, and 150dpi modes.
1
70C0h
LineAdjustment
Enable
R/W
0 or 1
Set Line adjustment On/Off
0:OFF /1:ON
1
70C4h LineAdjustmentDirection
R/W
0 or 1
Set transport direction
0: Normal (B → G → R
:
B-line first)
1: Opposit (R → G → B
:
R-line first)
0
70C8h LineAdjustmentRatio
R/W
1 to 16384
Resolution in transport direction
/
600dpi Ratio (0.03 to 4.0)
LineAdjustmentRatio =
Resolution(transport direction)
/600dpi
×
4096
4096
70CCh LineAdjustmentOfset
R/W
0 to 4096
Offset setting of Green pixel (0 to 1.0)
ܱ݂݂ݏ݁ݐ
=
ܴ݁݃݅ݏݐ݁ݎݒ݈ܽݑ݁
4096
0
Appendix A: Control register list
④
TM-XJ959A
Summary of Contents for KD Series
Page 3: ... Mitsubishi Electric Corporation 3 Chapter 1 Notice TM XJ959A ...
Page 17: ... Mitsubishi Electric Corporation 17 Chapter 2 Overview TM XJ959A ...
Page 40: ... Mitsubishi Electric Corporation 40 Chapter 3 Installation TM XJ959A ...
Page 59: ... Mitsubishi Electric Corporation 59 Chapter 4 How to control CIS TM XJ959A ...
Page 64: ... Mitsubishi Electric Corporation 64 Chapter 5 Getting started TM XJ959A ...