© Mitsubishi Electric Corporation
【
Remarks
】
1) Ignore return data from CIS due to change communication
baud rate. Because communication baud rate is changed
immediately on receiving this command and return data of this
command is send by the changed baud rate from CIS.
2) When using the UserSet _ # _ Save command, set the
TimeOut time back to the initial value.
If time out time is shorter
than 30 seconds, error is happened when executing
UserSet_#_Save command and be not able to save the setting
data.
5-2-5 UART Communication Setting
[Function]
UAER communication in Camera Link®
1) Switch baud rate
2) Setting time of time out
1) Switch baud rate for UART communication
It is able to select from 9.6kbps/19.2kbps/115.2kbps.
Initial value is 9.6kbps.
2) Setting time of time out for UART communication
Setting the time which is able to resume to receive the
command if sending incorrect command and no reply from
CIS.
Initial value is 30 seconds(Parameter Data = 150).
70
Address
Register name
R/W
Parameter
Data
Function
Initial
7004h
BaudRateSelect R/W
0 to 2
Switch baud rate of UART communication in Camera Link®
0: 9.6kbps, 1: 19.2kbps, 2: 115.2kbps
0
7008h
ContTimeOut
R/W 0 to 65535
Setting time of time out for UART communication in
Camera Link®
0:Disable, 1:0.2seconds afterwards every 0.2seconds
150
Camera Link® is a trade mark registered by AIA
(
Automated Imaging Association).
UART Specification
5-2 Setting
③
: UART Communication Setting
Item
Function
Baud Rate
9.6kbps,19.2kbps,115.2kbps
Data bit
8
Parity
None
Start bit
1
Stop bit
1
Flow Control
none
TM-XJ959A
Summary of Contents for KD Series
Page 3: ... Mitsubishi Electric Corporation 3 Chapter 1 Notice TM XJ959A ...
Page 17: ... Mitsubishi Electric Corporation 17 Chapter 2 Overview TM XJ959A ...
Page 40: ... Mitsubishi Electric Corporation 40 Chapter 3 Installation TM XJ959A ...
Page 59: ... Mitsubishi Electric Corporation 59 Chapter 4 How to control CIS TM XJ959A ...
Page 64: ... Mitsubishi Electric Corporation 64 Chapter 5 Getting started TM XJ959A ...