© Mitsubishi Electric Corporation
21
【
Data output timing
】
【
Data output timing
】
There is a latency to read-out a line data. The N-line latency is
designated from a timing of LED turn-ON as described on the
left drawing.
1) Period to read out the analog data of sensor pixels (1 line)
2) Period to convert the analog data into digital data and
rearrange the data position of each pixel in scanning
direction (1 line)
3) Period to process internal image processing (3 to 10 lines)
2-2 Principal technology of CIS
Line frequency
Internal read-out period
Digital output
LED turn-ON
Storing period
Read-out period
Data read-out period
N lines latency
1 line
TM-XJ959A
Summary of Contents for KD Series
Page 3: ... Mitsubishi Electric Corporation 3 Chapter 1 Notice TM XJ959A ...
Page 17: ... Mitsubishi Electric Corporation 17 Chapter 2 Overview TM XJ959A ...
Page 40: ... Mitsubishi Electric Corporation 40 Chapter 3 Installation TM XJ959A ...
Page 59: ... Mitsubishi Electric Corporation 59 Chapter 4 How to control CIS TM XJ959A ...
Page 64: ... Mitsubishi Electric Corporation 64 Chapter 5 Getting started TM XJ959A ...