© Mitsubishi Electric Corporation
66
5-2-1 Procedure of function settings
[Procedure of function settings]
1) This product contains several image processing function that
can be controlled over UART via Camera Link®.
2) Procedure of several function settings is described on the left
chart. Change each respective settings for your applications.
①
Initial Setting Select-1
②
Initial Setting Select-2
③
UART Communication Setting
④
Output Mode Setting
⑤
Switching Output Clock Frequency
⑥
Switching Number of Output Channel
⑦
Switching Resolution
⑧
Sync Signal Setting (Internal/External)
⑨
Illumination (LED) Control
⑩
Illumination (LED) Setting
⑰
Electric Shutter Setting
⑪
Dark Correction
⑫
White Correction
⑬
PGA
⑭
Line Adjustment
⑮
γ Correction
⑯
Mono output mode
⑱
Overlap Output setting
⑲
Output width setting
3) Control several functions (such as Dark/White Corrections) white
monitoring a time-dependent output-change in a continuous
operation.
[Remark]
1) When using Dark/White Correction, provide continuous External
Triggers or select Internal Sync. mode.
2) Generate your Dark/White Correction data every time when you
scan your object.
System Boot completion
Send Initial settings
Input Sync. Signal
※
⑪
Dark Correction
※
Illumination (LED)
Control (ON)
⑫
White Correction
※
Start data output
①
Initial Setting Select-1
②
Initial Setting Select-2
③
UART Communication Setting
④
Output Mode Setting
⑤
Switching Output Clock Frequency
⑥
Switching Number of Output Channel
⑦
Switching Resolution
⑧
Sync Signal Setting
(Internal/External)
⑨
Illumination (LED) Control
⑩
I
llumination (LED) Setting
/
⑰
Electric Shutter setting
⑲
Output width setting
※
When using Dark/White
Correction, please provide
continuous External Triggers or
select Internal Sync mode.
⑬
PGA
⑭
Line Adjustment
⑮
γ correction
⑯
Mono output mode
⑱
Overwrap output setting
Output external illumination sync
trigger signal for DXL series
5-2 Procedure of function settings
TM-XJ959A
Camera Link® is a registered trademark of AIA (Automated Imaging Association).
Summary of Contents for KD Series
Page 3: ... Mitsubishi Electric Corporation 3 Chapter 1 Notice TM XJ959A ...
Page 17: ... Mitsubishi Electric Corporation 17 Chapter 2 Overview TM XJ959A ...
Page 40: ... Mitsubishi Electric Corporation 40 Chapter 3 Installation TM XJ959A ...
Page 59: ... Mitsubishi Electric Corporation 59 Chapter 4 How to control CIS TM XJ959A ...
Page 64: ... Mitsubishi Electric Corporation 64 Chapter 5 Getting started TM XJ959A ...