Parameter unit (FR-PU07) / Parameter unit with battery pack (FR-PU07BB(-L))
83
3
key
2 Pr.List
1 Setting Mode
3 Set Pr.List
4 Def.Pr.List
SETTING MODE
0
〜
9:Ser Pr.No.
Select Oper
2
Pr.List
1 Appl.Grp
3 User List
4 Param Copy
12 RYA S
65 Retry
75 RES Mode
0, 1
2
1
3 Pr.List
3 Pr.List
4 Pr.Clear
4 Pr.Clear
5 Alarm His
5 Alarm His
6 AlarmClear
6 AlarmClear
7 INV.Reset
7 INV.Reset
8 T/Shooting
9 S/W
2 Clear All
1 1 Clear Pr.
Clear Pr.
Exec<WRITE>
Cancel<ESC>
Clear Pr.
Clear All Pr.
Exec<WRITE>
Cancel<ESC>
1 OHT
2 PUE
4 OV2
3 OV2
Fault indications.
The last eight faults are listed.
ALARM CLEAR
Exec<WRITE>
Cancel<ESC>
Clear All Pr.
ALARM CLEAR
Completed
Completed
11 Option
10 Selectop
12 PRCpy set
8 T/Shooting
9 S/W
11 Option
10 Selectop
12 PRCpy set
Not available for the FR-XC(-PWM) converter.
An indication "INV.RESET" appears, but this is the function to reset the multifunction regeneration converter.
1 Max.F
0 Pr Mode
2 Min.F
3 ROH Sel
⇒
⇒
RM
RL
RH
RT
Terminal name
∗2
ON
OFF
The values set in
Pr.3
to
Pr.16
are displayed.
RH:
Terminal LOH
MRS:
RES:
RUN:
SU:
IPF:
Terminal RYA
ABC2:
"- - - " means that no corresponding function is assigned to the terminal
(the corresponding parameter in
Pr.3
to
Pr.16
= "9999") or that the terminal does not have a function.
∗2
:
:
:
:
0
1
2
3
5 OV2
6 UVT
8 UVT
7 UVT
SET Pr.LIST
36 Fan Oper
0
DEF.Pr.LIST
0 Pr Mo
0
1 Max.F 60.00
2 Min.F 50.00
An indication "INV" (inverter) appears, but the software version of the multifunction regeneration converter is displayed.
*3
∗3
∗1
Perform parameter copy (writing) while the
SOF signal is ON.
∗1
∗5
∗5
The terminal names displayed correspond to the converter's terminals as shown below.
The function availability varies
depending on the software version
of the parameter unit.
Perform parameter copy
(writing) while the SOF signal
is ON.
99
3
17
⇒
Completed
Completed
Completed
Completed
∗4
∗4
Only the copy area 1 is available to
store a parameter setting of the
FR-XC series converter. Do not use
the copy area 2 for any other product
to preserve the converter parameter
setting stored in the copy area 1.
Doing so will delete the converter
parameter setting stored in the copy
area 1.
Terminal SOF
Terminal RES
Terminal RYB
Terminal RSO
Terminal ABC
INV.RESET
Exec<WRITE>
Cancel<ESC>
<S/W>
INV
:〇〇〇〇
A
OP1: A8NC
<option>
OP2: ----
OP3: ----
2 Copy area 2
1 Copy area 1
3 Copy area 3
1 Read VFD
Copy area 1
2 Write VFD
3 Verifing
:Select Char
Name:
0
00
READ:Decide Char
WRITE:DecideName
000
Overwrite area 1
WRITE:Executing
ESC:Cancel
000
Area 1 to VFD
WRITE:Executing
ESC:Cancel
000
Verify Area 1
WRITE:Executing
ESC:Cancel
Param Copy
Reading
Reading
Completed
Completed
Param Copy
Writing
Writing
Completed
Completed
Please Reset
Param Copy
Verifying
Verifying
Completed
Completed