175
Appendix 2
Instruction code list
∗1
The instruction code is used to write or read parameters through RS-485 communication or CC-Link communication.
(For RS-485 communication, refer to
. For CC-Link communication, refer to
∗2
For Parameter copy, Parameter clear, and All parameter clear,
○
indicates the function is available, and × indicates the function is not available.
∗3
These parameters are not cleared by Parameter clear command or All parameter clear command sent through RS-485 communication or CC-
Link communication. (For RS-485 communication, refer to
.) For CC-Link communication, refer to
∗4
Reading and writing are enabled when commands are sent through communication via the PU connector.
The parameter marked with the following option icon is available when the corresponding option is installed.
: FR-A8NC
Pr.
Name
Instruction
code
Parameter
Re
ad
Wr
it
e
Ex
te
nde
d
Copy
Clear
All clea
r
0
Simple mode selection
00 80
0
1
Maximum power supply
frequency
01 81
0
×
×
2
Minimum power supply frequency 02 82
0
×
×
3
LOH terminal function selection
03 83
0
×
4
SOF terminal function selection
04 84
0
×
7
RES terminal function selection
07 87
0
×
8
SOF input selection
08 88
0
×
9
OH input selection
09 89
0
×
11
RSO terminal function selection
0B 8B
0
×
12
RYA terminal function selection
0C 8C
0
×
16
ABC terminal function selection
10 90
0
×
22
Current limit level
16 96
0
23
Current limit level (regenerative)
17 97
0
31
Life alarm status display
1F 9F
0
×
×
32
Inrush current limit circuit life
display
20 A0
0
×
×
33
Control circuit capacitor life
display
21 A1
0
×
×
34
Maintenance timer
22 A2
0
×
×
×
35
Maintenance timer warning
output set time
23 A3
0
×
44
Instantaneous power failure
detection signal clear
2C AC 0
×
×
×
46
Watt-hour meter clear
2E AE
0
×
47
Energization time carrying-over
times
2F AF
0
×
×
×
48
Cumulative power monitor digit
shifted times
30 B0
0
52
PU main monitor selection
34 B4
0
57
Restart selection
39 B9
0
58
Free parameter 1
3A BA
0
×
×
59
Free parameter 2
3B BB
0
×
×
61
Key lock operation selection
3D BD 0
×
65
Retry selection
41 C1
0
67
Number of retries at fault
occurrence
43 C3
0
68
Retry waiting time
44 C4
0
69
Retry count display erase
45 C5
0
75
Reset selection / disconnected
PU detection / PU stop selection
4B CB 0
×
×
Parameter write selection
4D CD 0
80
Voltage control proportional gain
50 D0
0
81
Voltage control integral gain
51 D1
0
82
Current control proportional gain
52 D2
0
83
Current control integral gain
53 D3
0
117
PU communication station
number
11 91
1
118
PU communication speed
12 92
1
119
PU communication stop bit length 13 93
1
120
PU communication parity check
14 94
1
121
PU communication retry count
15 95
1
123
PU communication waiting time
setting
17 97
1
124
PU communication CR/LF
selection
18 98
1
145
PU display language selection
2D AD 1
×
×
168,
169,
269
Parameter for manufacturer setting. Do not set.
342
Communication EEPROM write
selection
2A AA
3
415
SW2 setting status
0F 8F
4
×
×
×
416
Control method selection
10 90
4
×
×
500
Communication error execution
waiting time
00 80
5
501
Communication error occurrence
count display
01 81
5
×
502
Stop mode selection at
communication error
02 82
5
520
Parameter for manufacturer setting. Do not set.
542
Station number (CC-Link)
2A AA
5
543
Transmission speed selection
(CC-Link)
2B AB
5
544
CC-Link extended setting
2C AC 5
896
Power unit cost
60 E0
8
989
Parameter for manufacturer setting. Do not set.
990
PU buzzer control
5 A DA 9
991
PU contrast adjustment
5B DB 9
×
Pr.
Name
Instruction
code
∗1
Parameter
R
ead
Wr
it
e
Extended
Co
py
∗2
Cl
ea
r
∗2
Al
l c
lea
r
∗2
Summary of Contents for FR-XC-11K
Page 75: ...MEMO 74 ...
Page 131: ...MEMO 130 ...
Page 155: ...MEMO 154 ...
Page 173: ...MEMO 172 ...