107
3
• Data reading format
Data a: Communication request data from the computer to the converter
Data c: Reply data from the converter to the computer (No data error detected)
Data c: Reply data from the converter to the computer (Data error detected)
Data e: Transmission data from the computer to the converter
∗1
A control code.
∗2
The converter station number is specified in hexadecimal in the range of H00 to H1F (stations No. 0 to 31).
∗3
Set the delay time.
When
Pr.123 PU communication waiting time setting
is set to other than "9999", create the communication request data without "delay time"
in the data format. (The number of characters decreases by 1.)
∗4
CR+LF code
When a computer transmits data to the converter, some computers automatically provide either one or both of the codes CR (carriage return)
and LF (line feed) at the end of a data group. In this case, the same setting is required for data sent from the converter to the computer. Use
Pr.124 PU communication CR/LF selection
for the CR+LF code setting.
Format
Number of characters
1
2
3
4
5
6
7
8
9
B
ENQ
Converter
station No.
Instruction
code
Sum
check
Format
Number of characters
1
2
3
4
5
6
7
8
9
10
11
E
STX
Converter
station No.
Read data
ETX
Sum
check
E1
STX
Converter
station No.
Read data
ETX
Sum
check
Format
Number of characters
1
2
3
4
5
D
NAK
Converter
station No.
Error
code
Format
Number of characters
1
2
3
4
C
(No data error
detected)
ACK
Converter
station No.
F
(Data error
detected)
NAK
Converter
station No.