Rating
157
6
400 V class
∗1
The harmonic suppression function is not pre-enabled in this model.
∗2
Selection example for 440 V power supply voltage.
∗3
IP00 for the FR-XCL.
∗4
The DC bus voltage is approx. 594 VDC at an input voltage of 400 VAC, approx. 653 VDC at 440 VAC, and approx. 713 VDC at 480 VAC.
∗5
One inverter for operation in the power regeneration mode.
∗6
Mass of the FR-XC alone.
∗7
Maximum capacity of regenerative power generated from the Mitsubishi Electric 4-pole standard motor in each axis.
Model FR-XC-H[ ]K
7.5
11
15
22
30
37
55
Harmonic suppression
C
o
mmon bus re
gener
ation mode
50
°C r
ating
Applicable inverter
capacity (kW)
Disabled
7.5
11
15
22
30
37
55
Enabled
⎯
⎯
⎯
18.5
22
37
55
Applicable motor
current (A)
Disabled
17
23
31
44
57
71
110
Enabled
⎯
⎯
⎯
38
44
71
110
Rated input current (A)
Disabled
Power driving
18
25
34
49
65
80
118
Regenerative
driving
14
20
27
39
54
66
98
Enabled
(HS)
Power/
regenerative
driving
⎯
⎯
⎯
37
43
71
104
Overload current rating
100% continuous / 150% 60 s
Power supply capacity
(kVA)
Disabled
17
20
28
41
52
66
100
Enabled
⎯
⎯
⎯
32
37
60
88
40
°C
r
atin
g
Applicable inverter
capacity (kW)
Disabled
7.5
11
15
22
30
37
55
Enabled
⎯
⎯
⎯
18.5
22
37
55
Applicable motor
current (A)
Disabled
18
25
34
48
63
78
120
Enabled
⎯
⎯
⎯
42
48
78
120
Rated input current (A)
Disabled
Power driving
20
27
37
53
72
88
129
Regenerative
driving
15
21
29
42
59
72
107
Enabled
(HS)
Power/
regenerative
driving
⎯
⎯
⎯
40
47
78
113
Overload current rating
100% continuous / 150% 60 s
Power supply capacity
(kVA)
Disabled
19
22
30
44
58
73
110
Enabled
⎯
⎯
⎯
34
40
66
96
Powe
r regeneration mode
50°C rating
Potential regenerative capacity (kW)
5.5
7.5
11
18.5
22
30
45
Rated current (A) (regenerative driving)
10
14
20
33
39
54
80
Overload current rating
100% continuous / 150% 60 s
40°C rating
Potential regenerative capacity (kW)
5.5
7.5
11
18.5
22
30
45
Rated current (A) (regenerative driving)
11
15
21
36
42
59
88
Overload current rating
100% continuous / 150% 60 s
Po
we
r s
ourc
e
Rated input AC voltage/
frequency
Disabled
Three-phase 380 to 500 V, 50/60 Hz
Enabled
⎯
⎯
⎯
Three-phase 380 to 480 V, 50/60 Hz
Permissible AC voltage
fluctuation
Disabled
Three-phase 323 to 550 V, 50/60 Hz
Enabled
⎯
⎯
⎯
Three-phase 323 to 506 V, 50/60 Hz
Permissible frequency
fluctuation
Disabled
±5%
Enabled
⎯
⎯
⎯
±5%
Input power factor
Enabled
⎯
⎯
⎯
0.99 or more (when load ratio is 100%)
Protection rating of structure (IEC 60529)
Open type (IP00)
Cooling system
Forced air
Number of connectable inverters
10
Approx. mass (kg)
5
5
6
10.5
10.5
28
28