181
Misoperation prevention and parameter setting restriction
4.16.2 Parameter write disable selection (Pr.77)
(1) Write parameters only during stop
(setting "0" initial value)
Parameters can be written only during a stop in the PU operation mode.
The shaded parameters in the parameter list
can always be written regardless of the operation mode and
operating status.
(2) Inhibit parameter write
(setting "1")
(3) Write parameters during operation
(setting "2")
Parameters can always be written.
The following parameters cannot be written when the drive unit is running if
Pr.77
= "2". Stop the drive unit when changing
their parameter settings.
You can select whether write to various parameters can be performed or not. Use this function to prevent parameter
values from being rewritten by misoperation.
Parameter
number
Name
Initial value
Setting range
Description
77
Parameter write selection
0
0
Write is enabled only during a stop.
1
Parameter can not be written.
2
Parameter write is enabled in any operation
mode regardless of operation status.
The above parameters can be set when
Pr.160 Extended function display selection
= "0".
Pr.77
can always be set independently from the operation mode and operation status.
Parameter write is not enabled.
(Read is enabled.)
Parameter clear and all parameter clear cannot be
performed, either.
The parameters given on the right can be written if
Pr.77
=
"1".
Parameter
number
Name
22
Torque limit level
75
Reset selection/disconnected PU detection/
PU stop selection
77
Parameter write selection
79
Operation mode selection
160
Extended function display selection
296
Password lock level
297
Password lock/unlock
997
Fault initiation
Parameters referred to
Pr.79 Operation mode selection
Parameter
number
Name
40
RUN key rotation direction selection
48
Second torque limit level
79
Operation mode selection
178 to 184
(Input terminal function selection)
190 to 192
(Output terminal function selection)
420
Command pulse multiplication numerator
(electronic gear numerator)
421
Command pulse multiplication denominator
(electronic gear denominator)
463
Position control rotation direction selection
535
Position control terminal input selection
537
Roll feed mode selection
658
Wiring resistance
736
Electromagnetic brake interlock time
785
PM control torque boost
795
DC brake torque boost
800
Control method selection
998
PM parameter initialization
999
Automatic parameter setting
Parameter
number
Name
Summary of Contents for FR-E700EX