51
Appendix 1: Specifications
8.2
NC-210 Beacon
Input/Output Operating
Specifications:
Inputs:
•
Wet contact pair, supplied voltage is nominally 3.6 V (absolute maximum
5 V).
•
Nominal current of 1.4 mA (external loop closed) and an absolute
maximum of 1.9 mA.
•
Follow manufacturer’s specifications for any attached equipment or
wiring.
•
End of Line Resistor: 10K ohms +/- 5% ½W
Outputs:
•
General Purpose Relays: dry contact form C, 40 VDC @ 500 mA max.
per relay
•
Dome Light Relays: dry contact form A, 24 VDC @ 500 mA max. per
relay
Install in accordance with the Canadian Electrical Code or the National
Electrical Code, and comply with all local regulations. Final acceptance
subject to the Local Authority Having Jurisdiction (AHJ).
Standards:
Standard for Safety for Hospital Signaling and Nurse Call Equipment –
UL 1069:2007 Ed.7+R:19 Feb2015
Signal Equipment CSA C22.2#205:2012 Ed.2 +E2015
Emergency Call Systems For Assisted Living And Independent Living
Facilities ANSI/UL 2560:2011 Ed.1 +R:28 May2015
CFR47 FCC Part 15 Subpart C 15.247:2012
CFR47 FCC Part 15 Subpart B:2012
IC RSS-210 Issue 8 December 2010 Annex 8
IC RSS-Gen Issue 3 December 2010+Notice DRS 2012-DRS0126
IC ICES-003 Issue 5 August 2012
IC RSS-102 Issue 4 March 2010
Power Options:
Input Power:
•
120 VAC @ 6.0 mA nominal
Wireless Characteristics:
ZigBee:
•
Frequency: 2.4 GHz
•
Network type: 802.15.4 wireless mesh network
•
Range: 23 m (75 ft) with line of sight
Ultrasonic transmitter:
•
Frequency: 40 kHz
•
Range: 9.1 m (30 ft)