4-2.
REMOUNTING THE EEPROM (IC3A)
NOTES
• When the Master Board is replaced with a new one, be sure to demount EEPROM
(IC3A) from the old Master Board and mount it on the new Master Board.
• If the Master Board has been replaced, but the EEPROM (IC3A) has not been
remounted, be sure to replace the Imaging Cartridge with a new one at the same time.
1. Remove the Master Board. (For details, see 2-2. REMOVAL OF CIRCUIT BOARDS
AND OTHER ELECTRICAL COMPONENTS.)
2. Demount the EEPROM (IC3A) from the new Master Board.
3. Demount the EEPROM (IC3A) from the old Master Board and remount it onto the new
Master Board.
4011D092AA
New EEPROM
New Master
Board
Old EEPROM
Old Master
Board
NOTE
• Note the alignment notch on the EEPROM (IC3A)
when mounting the IC.
1171D049AA
A
A
Summary of Contents for Di251
Page 1: ...Di251 Di351 SERVICE MANUAL GENERAL 4011 7990 11 ...
Page 2: ...INDEX GENERAL GENERAL MECHANICAL ELECTRICAL ...
Page 3: ...GENERAL ...
Page 18: ...MECHANICAL ELECTRICAL ...
Page 24: ...M 4 3 DRIVE SYSTEM 1 Scanner Motor M10 2 Main Motor M2 3 I C Motor M1 1 3 2 4011M002AA ...
Page 71: ...Di251 Di351 SERVICE MANUAL FIELD SERVICE 4011 7991 11 ...
Page 83: ...Di251 Di351 Allgemein Mechanik Elektrik Rev 1 1 0 03 01 I 1 INSTALLATION 3 ...
Page 88: ...Di251 DI351 Rev 1 1 0 03 01 I 6 ...
Page 93: ...I 5 Di251 Di351 Rev 11 0 0 03 01 10 Grounding plate screws 3 1 2 3 4 5 6 7 8 9 10 ...
Page 99: ...I 11 Di251 Di351 Rev 11 0 0 03 01 6 Fit the Exit Tray 7 Close the Finisher Cover ...
Page 178: ...I 90 Di251 Di351 Rev 1 1 0 0 03 01 ...
Page 179: ...DIS REASSEMBLY ADJUSTMENT 10230 ...
Page 241: ...SWITCHES ON PWBs TECH REP SETTINGS 17196 ...
Page 296: ...TROUBLESHOOTING 14413 ...