5-3.
Settings in the Security Mode
Touch Panel
Display
Setting (The default is
).
Total Counter
Select the condition by which the Counter count is increased.
Size Counter
Select the size of the paper to be counted by the Size Counter.
Copy Kit Counter
Select whether to enable or disable the “Copy Kit count.”
Copy Kit
Enter a value for the Copy Kit Counter.
When the current value reaches the set value, the following display is
given.
• Copy Kit Counter setting
Mode 2: The icon “
” appears in the sub-message display.
Mode 3: The maintenance call reminder “M4” appears and the
initiation of a new copy cycle is inhibited.
<Procedure>
1. Touch “Set.”
2. Press the Clear key to clear the current setting.
If the setting is accidentally cleared, press the Interrupt key to
undo the clearing operation.
3. Enter the desired value from the 10-Key Pad.
4. Touch “Current.”
5. Press the Clear key to clear the current value.
If the current value is accidentally cleared, press the Interrupt key
to undo the clearing operation.
Plug-In Counter
Select the condition by which the Counter count is increased.
Highlighted
1 Copy per 1 copy cycle
Mode 2
Multiple count-up according to paper size 1/2-sided
copying
Mode 3
Multiple count-up according to paper size 1/2-sided
copying
Mode 1
No Count
A3/11x17
A3/B4/11x17/Legal
A3/B4/11x17/11x14/Legal/FLS
Disables the Copy Kit counter.
Mode 2
Copying not inhibited after the count reaches the
present value.
Mode 3
Copying inhibited after the count reaches the
present value.
Mode 1
Copy Made
Copy Cycles
Summary of Contents for Di251
Page 1: ...Di251 Di351 SERVICE MANUAL GENERAL 4011 7990 11 ...
Page 2: ...INDEX GENERAL GENERAL MECHANICAL ELECTRICAL ...
Page 3: ...GENERAL ...
Page 18: ...MECHANICAL ELECTRICAL ...
Page 24: ...M 4 3 DRIVE SYSTEM 1 Scanner Motor M10 2 Main Motor M2 3 I C Motor M1 1 3 2 4011M002AA ...
Page 71: ...Di251 Di351 SERVICE MANUAL FIELD SERVICE 4011 7991 11 ...
Page 83: ...Di251 Di351 Allgemein Mechanik Elektrik Rev 1 1 0 03 01 I 1 INSTALLATION 3 ...
Page 88: ...Di251 DI351 Rev 1 1 0 03 01 I 6 ...
Page 93: ...I 5 Di251 Di351 Rev 11 0 0 03 01 10 Grounding plate screws 3 1 2 3 4 5 6 7 8 9 10 ...
Page 99: ...I 11 Di251 Di351 Rev 11 0 0 03 01 6 Fit the Exit Tray 7 Close the Finisher Cover ...
Page 178: ...I 90 Di251 Di351 Rev 1 1 0 0 03 01 ...
Page 179: ...DIS REASSEMBLY ADJUSTMENT 10230 ...
Page 241: ...SWITCHES ON PWBs TECH REP SETTINGS 17196 ...
Page 296: ...TROUBLESHOOTING 14413 ...