18. Remove one shoulder screw and the Fusing
Guide Assy.
19. 1Remove one screw, one shoulder screw, and
the cover.
4011D072AB
20. Snap off one retaining ring E type and remove
the Front Pressure Lever Assy and bearing.
4011D073AA
21. Snap off one retaining ring E type and remove
the Rear Pressure Lever Assy and bearing.
22. Remove the Right Fusing Roller.
4011D074AB
23. Remove three screws, frame, spring, and the
lever.
4011D075AB
4011D076AB
NOTES
• Study the illustration for how the spring is installed.
• After the spring has been installed, move the lever
in the direction of the arrow to make sure that it is
returned by the tension of the spring.