I-42
Di251/Di351
Rev. 1.1.0.0/03.01
left
1.8.7
Adjusting the Document Stop Position
1. Access the initial Tech. Rep. Mode screen.
(Refer to the Service Manual for the
procedure.)
2. Touch “Tech. Rep. Choice”.
3. Touch “ADFR”.
4. Touch “Original Stop Position”.
1.8.8
Adjusting the Document Stop Position
1. Select the “2-Side Set” mode.
2. After pressing the Clear key, use the key pad
to enter the adjustment.
Use the * key to switch b and -.
+: Adjusts in direction C
-: Adjusts in direction D
3. Press the Panel Reset Key to display the
Service Mode screen and touch the Stop key.
Check the document stop position again.