FrameMaker Ver.5.5(PC) Di251/Di351 TROUBLESHOOTING
05.03.01
T-61
6.
ABORT CODES
• The copier displays an abort code on the Touch Panel as it becomes unable to process
tasks properly through its software control.
6-1.
List of Abort Codes
• When the system program is aborted, the copier attempts to restart it automatically. If it
fails to restart the program, check the electrical component, unit, option, and connection
relating to the specific type of the abort condition.
Description
Code
Relevant Electrical Components, Units, and Options
OS processing sys-
tem failure
0x00000000
to 0x000fffff
MFB2 Board
Device control sys-
tem failure
0x00100000
to 0x001fffff
MFB2 Board, FAX1 Board, NCUK Board, IIF2
Board, MPK Board, COD Board, FPLAN Board,
CEN Board, expansion memory, OT-102, JS-201,
FN-109, FN-110, FN-504, JS-100
Copy control system
failure
0x00200000
to 0x002fffff
MFB2 Board
Operation system
failure
0x00300000
to 0x003fffff
MFB2 Board, Touch Panel, Panel Board
Network function
Web processing sys-
tem failure
0x00400000
to 0x004fffff
MFB2 Board, FPLAN Board, CEN Board
Conversion process-
ing system failure
0x00500000
to 0x005fffff
MFB2 Board
Encoding process-
ing system failure
0x00600000
to 0x006fffff
MFB2 Board, COD Board, MPK Board
File control system
failure
0x00700000
to 0x007fffff
MFB2 Board, expansion memory
G3 protocol process-
ing system failure
0x00800000
to 0x008fffff
MFB2 Board, FAX1 Board, NCUK Board, IIF2
Board, MPK Board
G3 device control
system failure
0x00900000
to 0x009fffff
MFB2 Board, FAX1 Board, NCUK Board, IIF2
Board, MPK Board
Abort Code
4011T536AA
Summary of Contents for Di251
Page 1: ...Di251 Di351 SERVICE MANUAL GENERAL 4011 7990 11 ...
Page 2: ...INDEX GENERAL GENERAL MECHANICAL ELECTRICAL ...
Page 3: ...GENERAL ...
Page 18: ...MECHANICAL ELECTRICAL ...
Page 24: ...M 4 3 DRIVE SYSTEM 1 Scanner Motor M10 2 Main Motor M2 3 I C Motor M1 1 3 2 4011M002AA ...
Page 71: ...Di251 Di351 SERVICE MANUAL FIELD SERVICE 4011 7991 11 ...
Page 83: ...Di251 Di351 Allgemein Mechanik Elektrik Rev 1 1 0 03 01 I 1 INSTALLATION 3 ...
Page 88: ...Di251 DI351 Rev 1 1 0 03 01 I 6 ...
Page 93: ...I 5 Di251 Di351 Rev 11 0 0 03 01 10 Grounding plate screws 3 1 2 3 4 5 6 7 8 9 10 ...
Page 99: ...I 11 Di251 Di351 Rev 11 0 0 03 01 6 Fit the Exit Tray 7 Close the Finisher Cover ...
Page 178: ...I 90 Di251 Di351 Rev 1 1 0 0 03 01 ...
Page 179: ...DIS REASSEMBLY ADJUSTMENT 10230 ...
Page 241: ...SWITCHES ON PWBs TECH REP SETTINGS 17196 ...
Page 296: ...TROUBLESHOOTING 14413 ...