FrameMaker Ver5.5E(PC)Di251/Di351 MECHANICAL/ELECTRICAL
05.03.01
M-26
13-4.
Toner Bottle Home Position Detection Mechanism
• The Toner Bottle Home Position Sensor detects the Toner Bottle at its home position.
When the Toner Bottle is at the home position (stationary), its toner supply port should
face up.
13-5.
Toner Bottle Vibration Mechanism
• When the dents in the Toner Bottle move past the protrusion of the Bottle Holder, the
Toner Bottle is vibrated to prevent some of the toner from remaining unconsumed in the
bottle.
Electrical Component
Control Signal
Activated Deactivated
Wiring Diagram
PC10
PJ15A-4B
L
H
4 to 5-F
4011M004AA
Toner Bottle Home Position
Sensor PC10
1139M029AA