(2)
Original Size Detecting Sensor Adjustment (F7-1)
Make this adjustment after any of the following procedures have been performed:
• Memory Clear
• A faulty original size detection occurs
• Replacement of the CCD Unit and Scanner parts (including the Exposure Lamp)
• Original Size Detecting Sensor addition or replacement
• ROM/RAM Board replacement
Adjustment Procedure
2. Call the Tech. Rep. Mode to the screen.
3. Touch "Function" to display the Function menu.
4. Touch "F7-1".
5. Press the Start key to run the Original Size Detecting Sensor Adjustment function.
6. Turn OFF and ON the Power Switch.
NOTE
• The Start key remains lit up orange while this function is being run and lights up green as
soon as the sequence is completed.
1. Stack five sheets of blank A3 or 11×17 paper on
the Original Glass and lower the Original Cover.
1167D110AB
Summary of Contents for Di251
Page 1: ...Di251 Di351 SERVICE MANUAL GENERAL 4011 7990 11 ...
Page 2: ...INDEX GENERAL GENERAL MECHANICAL ELECTRICAL ...
Page 3: ...GENERAL ...
Page 18: ...MECHANICAL ELECTRICAL ...
Page 24: ...M 4 3 DRIVE SYSTEM 1 Scanner Motor M10 2 Main Motor M2 3 I C Motor M1 1 3 2 4011M002AA ...
Page 71: ...Di251 Di351 SERVICE MANUAL FIELD SERVICE 4011 7991 11 ...
Page 83: ...Di251 Di351 Allgemein Mechanik Elektrik Rev 1 1 0 03 01 I 1 INSTALLATION 3 ...
Page 88: ...Di251 DI351 Rev 1 1 0 03 01 I 6 ...
Page 93: ...I 5 Di251 Di351 Rev 11 0 0 03 01 10 Grounding plate screws 3 1 2 3 4 5 6 7 8 9 10 ...
Page 99: ...I 11 Di251 Di351 Rev 11 0 0 03 01 6 Fit the Exit Tray 7 Close the Finisher Cover ...
Page 178: ...I 90 Di251 Di351 Rev 1 1 0 0 03 01 ...
Page 179: ...DIS REASSEMBLY ADJUSTMENT 10230 ...
Page 241: ...SWITCHES ON PWBs TECH REP SETTINGS 17196 ...
Page 296: ...TROUBLESHOOTING 14413 ...