I-45
Di251/Di351
Rev. 11..0.0/03.01
right
7. Press the Panel Reset Key to display the
Service Mode screen and touch the Stop key.
Check the document stop position again.
1.8.12
Checking and adjusting the position of the rear guide plate
1. Set the copier into the following modes:
Auto Paper Select
One-sided Original
One-sided Copy
2. Place a sheet of A4 or Letter paper crosswise
onto the Document Feed Tray.
3. Press the Start Key and open the paper guide
F1 as soon as the scanning starts.
4. After the paper is fed onto the Original Glass,
open the Duplexing Document Feeder gently.
NOTE
When the Duplexing Document Feeder is
opened quickly, the paper will be knocked out of
position.
Panel Reset