FrameMaker Ver5.5E(PC) Di251/Di351 SWITCHES ON PWBs/TECH. REP. SETTINGS
05.03.01
S-25
(5)
Function
• This function allows the Tech. Rep. to make the various function tests and adjustments.
Touch Panel
Display
Setting
Device
Shows the numbers of prints for different applications. It also allows
the Tech. Rep. to clear each counter.
Maintenance
Set different count values for the Maintenance Counter.
When the count reaches the preset value, the icon “
” appears in the
Sub-Message Display.
<Procedure>
1. Touch “Maintenance (Set)”.
2. Press the Clear key to clear the current value.
Press the Interrupt key to undo the clearing operation, restoring
the original value.
3. Enter the value from the 10-Key Pad.
Touch Panel
Display
Setting
F1
<Paper Passage>
A check is made for paper passage performance.
<Procedure>
1. Select the paper source.
2. Press the Start key to start the paper passage cycle.
3. Press the Stop key to stop the paper passage cycle.
F2
This test is for factory adjustment only and should NOT be used.
F7-1
<Original Size Detecting Sensor Adjustment>
Automatically adjusts the threshold level of the Original Size Detecting
Sensor.
✽
For details, see DIS/REASSEMBLY, ADJUSTMENT.
F8
<ATDC Sensor Automatic Adjustment>
This test is for factory adjustment only and should NOT be used.
F12
<Test Pattern>
Outputs the test pattern.
<Procedure>
1. Select the paper source.
2. Press the Start key to start the output sequence.
3. Press the Stop key to stop the output sequence.
Display
Description
Copier
No. of prints made by copier
Printer
No. of prints made by printer
Report Print
No. of report prints made
FAX Print
No. of fax prints made
FAX Transmission No. of prints made for fax transmission
Mail Transmission
No. of prints made for mail transmission
Summary of Contents for Di251
Page 1: ...Di251 Di351 SERVICE MANUAL GENERAL 4011 7990 11 ...
Page 2: ...INDEX GENERAL GENERAL MECHANICAL ELECTRICAL ...
Page 3: ...GENERAL ...
Page 18: ...MECHANICAL ELECTRICAL ...
Page 24: ...M 4 3 DRIVE SYSTEM 1 Scanner Motor M10 2 Main Motor M2 3 I C Motor M1 1 3 2 4011M002AA ...
Page 71: ...Di251 Di351 SERVICE MANUAL FIELD SERVICE 4011 7991 11 ...
Page 83: ...Di251 Di351 Allgemein Mechanik Elektrik Rev 1 1 0 03 01 I 1 INSTALLATION 3 ...
Page 88: ...Di251 DI351 Rev 1 1 0 03 01 I 6 ...
Page 93: ...I 5 Di251 Di351 Rev 11 0 0 03 01 10 Grounding plate screws 3 1 2 3 4 5 6 7 8 9 10 ...
Page 99: ...I 11 Di251 Di351 Rev 11 0 0 03 01 6 Fit the Exit Tray 7 Close the Finisher Cover ...
Page 178: ...I 90 Di251 Di351 Rev 1 1 0 0 03 01 ...
Page 179: ...DIS REASSEMBLY ADJUSTMENT 10230 ...
Page 241: ...SWITCHES ON PWBs TECH REP SETTINGS 17196 ...
Page 296: ...TROUBLESHOOTING 14413 ...