①
Special data area (4 stations, 2 stations)
When the set value is registered by using the setting value writing request (request 1), the
set value is set in each area.
Details of each set value are shown as follows;
Data type
Setting range
S1
32 bit binary with sign
-999999 ~ 999999
S2
32 bit binary with sign
-999999 ~ 999999
S3
32 bit binary with sign
-999999 ~ 999999
S4
32 bit binary with sign
-999999 ~ 999999
Full
32 bit binary with sign
0 ~ 999999
Near Zero
32 bit binary with sign
0 ~ 999999
②
General data area (4 stations, 2 stations)
When the set value or data is registered by using the general command request (request 2),
the set value is set in this area
Details of each set value are shown as follows;
Data type
Setting range
S0
32 bit binary with sign
-999999 ~ 999999
S1
32 bit binary with sign
-999999 ~ 999999
S2
32 bit binary with sign
-999999 ~ 999999
S3
32 bit binary with sign
-999999 ~ 999999
S4
32 bit binary with sign
-999999 ~ 999999
Full
32 bit binary with sign
0 ~ 999999
Near Zero
32 bit binary with sign
0 ~ 999999
③
Command No. (4 stations, 2 stations)
When the set value or data is registered by using the general command request (request 2),
the command No. is set in this area.
The content of the general data area is set depending on the command set in this
command area.
Data type
: 8 bit binary
Setting range
: 0 ~ 255
④
Operating mode (4 stations, 2 stations)
When the operation mode is changed by using the operation mode changeover request
(request 3), the mode number is set in this area.
This function is prepared for future expansion.
Data type
: 8 bit binary
Setting range
: 0 ~ 255
84
C
C
-Li
nk