36
Se
tti
ng
o
f F
un
ct
io
n
5-2. Details of C function data
Reference No.
Item
Function No.
Set value
Contents
6-1
Display position of
decimal point
CF-01
●
0
No decimal point
1
1234.5
2
123.45
3
12.345
4
1.2345
6-2
A/D sampling rate
CF-02
0
50 times/s
1
100 times/s
2
250 times/s
●
3
500 times/s
6-3
Condition of overload
display
CF-03
0
At exceeding | Weighing ca 9D |
●
1
At exceeding 110 % of Weighing capacity
2
At exceeding -20D
~
(Weighing c9D)
6-4
Comparative operation
display synchronization
CF-04
●
0
Invalid
1
valid
6-5
Unit
CF-05
0
No unit
1
g
●
2
kg
3
t
4
lb
5
N
6
Pa
7
kN
8
kPa
9
MPa
6-6-1
Operating condition of
ZERO set
CF-10
0
Operation on stable condition
●
1
Operation by unconditional
6-5-2
Effective range of ZERO
set
CF-11
00
~
30 Unit :
±
1 % of weighing capacity
00 : ZERO set off
●
02
6-7-1
Target of ZERO tracking
CF-12
0
Gross value and Net value
●
1
Gross (Only when gross weight displays.)
6-7-2
Date width of ZERO
tracking
CF-13
000
~
999 Unit : 0.1 D
●
000
000 : ZERO tracking is OFF
6-7-3
Time width of ZERO
tracking
CF-14
00
~
99 Unit : 0.1 s
●
00
00 : ZERO tracking is OFF
6-8-1
Operation of power on
CF-15
●
0
Invalid
1
valid
6-9-1
Operating condition of
tare weight cancellation
CF-16
●
0
in steady by 0 < Gross value <= Weighing capacity
1
in normal by 0 < Gross value <= Weighing capacity
2
in steady by Gross weight <= Weighing capacity
3
in normal by Gross weight <= Weighing capacity
6-10
Date stored
CF-17
000
~
111
●
100
0 : Internal RAM
1 : EEPROM
10
0
: Data of ZERO set.
10
1
: Tare weight cancellation
10
2
: Setting mode of simple comparison mode, and
setting data of 5 steps of comparator mode.
●
: default