18-1. Speci
fi
cations for analog
Bridge power supply
DC5 V
±
0.25 V within 60 mA, with sensing
Applicable transducer
Up to 4 pieces of strain gage applied transducers (350 ohm) can be
connectable.
Input sensitivity
0.15
μ
V/d or more (d
=
minimum scale)
* 0.2
μ
V/d (In case of applying CE conformity standard.)
Input range
-3.1 mV/V to 3.1 mV/V
ZERO adjustable range
±
2.5 mV/V
Non-linearlty
0.01%F.S.
Temp.
coef
fi
cient
ZERO
±
0.2
μ
V/
℃
(In the calibration by the input sensitivity of 0.15
μ
V/d or more.)
Sensitivity
±
0.001 5 %F.S./
℃
(In the calibration by the input sensitivity of 0.15
μ
V/d or more.)
Input noise
±
0.2
μ
Vp-p or less (At the default setting of analog
fi
lter, digital
fi
lter
and stabilization
fi
lter.)
Analog
fi
lter
Approx. 4 Hz (Changeable to 2Hz, 6Hz, 8Hz or 10Hz)
A/D sampling
500 times/s (Changeable to 250 times/s, 100 times/s or 50 times/s.)
A/D internal resolution
24 bits
18-2. Speci
fi
cations for digital
Lo
ad
d
is
pl
ay
Display range
-99 999 ~ 99 999
Display increment
1 (Changeable to 2, 5, 10, 20 or 50)
Display unit
FSTN liquid crystal (With umber color LED back light.)
Over display
[-OL] display at minus over, [OL] display at plus over
AD value over display [-OVF] display at minus over, [OVF] display at plus over
Condition display
ZERO, SPAN, mV/V, STABLE, TARE, GROSS, NET, CZ, LOCK, HOLD,
ERROR
Display rate
2 times/s
Judgement display
OUT1, 2, 3, 4, 5
Decimal point display
Changeable to No display, 10
1
, 10
2
,10
3
or 10
4
.
Unit display
Changeable to No display, g, kg, t, N, kN, lb, Pa, kPa or MPa.
18-3. Interface
External control input
3 functions in the following can be arbitrarily selected.
OFF, SERO set, ZERO clear, Tare weight cancellation, Tare weight
cancellation clear, Hold, Net/Gross value
* Above are pulse input, and effective only once at the pulse width of 50
ms or more.
Hold, NET value display (With ON, a NET weight is displayed when the
Gross weight is shown.)
* Above are level input, and effective during the input of short for 50 ms
or more.
External control output
5 functions in the following can be arbitrarily selected.
OFF, RUN, Stable, During canceling the Tare weight, Display of
gross value, Display of net value, Center zero, During the hold, Error,
Abnormal weight, Near Zero, OK (S0), Full
fl
ow (S1), Medium
fl
ow (S2),
Dribble
fl
ow (S3), Over (S4), Under, Full
18. Speci
fi
cations
138
Sp
ec
ific
at
io
ns & O
th
er
s