④
Reading out the condition 1 (Host
→
CSD-892-73)
2
4
6
@
0
0
4
0
Terminator
Return (CSD-892-73
→
Host)
2
4
6
8
10
12
14
@
0
0
4
0
a
b
c
d
e
f
g
h
Terminator
a : STABLE
[1] = ON, [0] = OFF
b : No use
[0] = Fixed
c : TARE WEIGHT
[1] = ON, [0] = OFF
d : GROSS value
[1] = ON, [0] = OFF
e : NET value
[1] = ON, [0] = OFF
f : ZERO
[1] = ON, [0] = OFF
g : HOLD
[1] = ON, [0] = OFF
h : ERROR
[1] = ON, [0] = OFF
⑤
Reading out the condition 2 (Host
→
CSD-892-73)
2
4
6
@
0
0
4
1
Terminator
Return (CSD-892-73
→
Host)
2
4
6
8
10
12
14
@
0
0
4
1
a
b
c
d
e
f
g
h
Terminator
a : NEAR ZERO
[1] = ON, [0] = OFF
b : FULL FLOW/S1
[1] = ON, [0] = OFF
c : MEDIUM FLOW/S2
[1] = ON, [0] = OFF
d : DRIBBLE FLOW/S3
[1] = ON, [0] = OFF
e : OVER/S4
[1] = ON, [0] = OFF
f : OK/S0
[1] = ON, [0] = OFF
g : UNDER
[1] = ON, [0] = OFF
h : FULL
[1] = ON, [0] = OFF
Command No.
Operation
40
Reading out the condition 1
Command No.
Operation
40
Reading out the condition 1
Space
Condition
Command No.
Space
Condition
Command No.
Command No.
Command No.
116
U
S
B
(R
S
-2
32
C
)