- 4.23 -
Move the carriage to the left maintenance station [CARRIAGE]
This function move the carriage to the left maintenance station to chack the head, to clean the
nozzle surface and to do maintenance of carriage.
STEPS:
1.
Select [CARRIAGE] from [MAINTENANCE].
(See page 4.3)
2.
Press the [ENTER] key.
3.
Press the [ENTER] key.
The carriage is moved to the left maintenance station.
4.
Remove the left maintenance cover.
Lossen the 3 screws attached at the bottom of the main unit
and remove 1 screw on the left maintenance cover and then
remove the left maintenance cover.
5.
Do the maintenance of the carriage.
Using the supplied swab with cleaning liquid, remove ink around
the head.
• Never rub the surface of the nozzle, as this
may cause discharge failure.
• Use the cleaning liquid (SPC-0137:optional
item).
M A I N T E N A N C E
C A R R I A G E
< e n t >
C A R R I A G E
MA I N T
C A R R I A G E o u t < e n t >
C AR R I A GE
MA I N T
C OM P L E T E D
: en t
Summary of Contents for DS-1600
Page 2: ......
Page 110: ......
Page 146: ...4 36...
Page 171: ......
Page 172: ...Printed in Japan D201421 MIMAKI ENGINEERING CO LTD 2006 NH...