- 2.13 -
Checking and solving nozzle clogging
STEPS:
1.
The machine enters the LOCAL mode.
2.
Press the [TEST] key.
3.
Press the [TEST] key or [ENTER] key.
The machine plots the test pattern.
After the test print is done, the table moves to the front and
turns to LOCAL mode.
4.
Check the test patterns.
Operation is completed in normal cases.
If a failure occurs, perform the following operation
5.
Press the [CLEANING] key.
6.
Press the XY keys [ ] or [ ] to select the head
block for cleaning.
(Refer to page.1.10 [Ink station] )
7.
Press the XY [ ] or [ ] keys to set on/off of the
blocks that need cleaning.
Do not execute the head cleaning as for [-----].
8.
Press the [ENTER] key.
9.
Press the XY [ ] or [ ] keys to select the type
of cleaning.
Normal
:
Select this if there is any missing line.
Soft
:
Select this if any line is bent.
Strong
:
When printing trouble is not solved even with
[Norma]l or [Soft].
<< LOCAL >>
X =1010
Y = 1860
TEST PRINT
< ENT >
∗∗
∗∗
Clean
: 1256 - - - -
Select
: ABEF -- - - -
On / Off
Cleaning
Type
: Normal
Normal/Soft/Strong
<< LOCAL >>
X =1010
Y = 1860
Clean
: 1 2 5 6 3 4 7 8
Select
: A B E F C D G H
[1256ABEF] / [3478CDGH]
Summary of Contents for DM3-1810S
Page 2: ......
Page 20: ... xvi ...
Page 34: ... 1 14 ...
Page 76: ... 3 20 ...
Page 112: ... 6 10 ...
Page 131: ... A 19 TYPE Refresh Level3 TYPE mm inch mm X Level0 Level3 X inch Function flowchart ...
Page 141: ... A 29 MAIN Ver1 00 I F Ver Function flowchart ...
Page 144: ...D201258 1 10 30032007 ...
Page 145: ......
Page 146: ...PrintedinJapan MIMAKI ENGINEERING Co Ltd FW 5 10 NH ...