Using for the first time
35
The prompt for water intake appears
and the triangle
flashes:
Open the door.
Pull the water intake pipe forwards
(located below the control panel on
the left).
Immerse the end of the water intake
pipe in the container with the tap
water.
Confirm with
OK
.
The water intake process will begin.
The amount of water required will be
drawn up into the oven. The quantity of
water specified is higher than actually
required, leaving a small amount in the
container.
Remove the water container after the
water intake process.
Close the door.
You will hear the pump briefly as the
remaining water in the water intake pipe
is drawn into the oven.
After a short time a burst of steam is
injected automatically.
Risk of injury!
Steam can cause scalding.
Do not open the door during a steam
burst.
Heat the empty oven for at least an
hour.
After at least an hour:
Turn the function selector to
•
.