99
6.7 Program change (PRG)
Using this function you can make the Matrix send out Program Change commands to all
your expanders when you change Matrix Programs. A separate program number can be given to
every MIDI channel of every output of the Matrix.
➔
This function works on outputs only.
This function works on outputs only.
This function works on outputs only.
This function works on outputs only.
$
Call up the Program Change Mapping function:
»
PRG
«
.
In the top right of the display you will see the number and name of the current MIDI output.
LEDs light on the number keys representing outputs which already have settings.
$
Select an output using
to
.
➊
Change “
Ch 1
“ to the MIDI channel on which you wish to send a Program Change
command.
➋
Press
.
➌
Using
!
, select the program number you wish to send whenever this Matrix Program is
selected.
➍
If you press
, the command will be sent, so that you can check the effect on your
expander.
➎
If necessary, move the blinking cursor with
across the two parameters and
program any other settings you need.
➐
The “
Read
“ function allows you to check the settings of the current output.
➏
The “
CLR
“ function allows you to delete the currently displayed Program Change.
%
Quit this function by pressing
.
Using “
BNK
“ you can define additional a Bank Select (Controller 0 and 32) to the currently
Program Change. The values for Controller 0 and 32 are together the required bank number, but
they are programed seperately. For the correct values please refer the manual of your sound device.
$
Select
»
BNK
«
.
➊
Using
, you can move the blinking cursor across the two parameters.
➋
Using
!
, you can change the values.
➌
The “
Read
“ function allows you to check the settings without changing them
&
Using the “
Read
“ function Program Change values, handled with the Bank Select, will be
displayed completely. For all others, only the PC value will be shown.
Program Change: 1:
1
2 3 4 5 6 7 8
Program Change: Ch 1 1:
TMR CLR BNK Read
Program Change: Ch 1 1:
TMR CLR BNK Ctrl.0: 0 Ctrl.32: 0 Read