Microtronix Access User Guide
5 X.25 WAN Interfaces Configuration
This section allows for configuration and administration of the WAN (Wide Area Network) interfaces for
X.25. Click on each item in the
X.25 WAN
section of the main menu to invoke the configuration forms
and status displays.
5.1 L1 - Device
This form allows any of the X.25 physical layer parameters to be set. The interface type MUST match
the attached equipment, and the clock source MUST be compatible. If an internal clock source is
selected, the clock rate must not exceed the attached peer's capability.
5.1.1 Physical Layer (HDLC) Setup
1.In the
Device
field, select the WAN interface to configure. Once selected, the current settings for
that interface will be displayed.
2.Modify the parameters to be compatible with the attached device
.
3.In order for the configuration to take effect, the
Restart WAN Interface
box must be checked.
Otherwise the configuration will be saved, but will not take effect until the next time the interface is
restarted.
4.Click the
Update
button to save changes, and restart the interface if selected.
5.1.2 HDLC Parameters
Device:
The X.25 WAN interface being configured. This will be hdlc0 (WAN port 0), or hdlc1
(WAN port 1).
Interface Type:
The physical interface type to be used. The supported types are: RS232/V.24,
V.35, X.21, RS449/V.36, RS530, and RS530a. Refer to the
Cables and Connectors
section to
determine the appropriate cable for the application.
Clock Source:
Specifies the source of the synchronous clocking (timing) signal.
30