Serial Commands
E
Vision HAWK Smart Camera Guide
E-3
ONLINE
Starts all inspections.
OFFLINE
Stops all inspections.
TRIGGER
Triggers an inspection.
vt [n]
Triggers an inspection by pulsing a Virtual I/O point.
For example:
vt 1
will return pulse
VIO1
. The inspection will run if it is configured to use
VIO
1
as a trigger.
If specified, the VIO index must be in the allowed range for Virtual I/O
points within Visionscape. The virtual I/O line will be set high then low.
If VIO Index is not specified, VIO1 is assumed.
Fail Return:
Return
!ERROR
followed by the reason for the failure.
For example:
!ERROR No such trigger
when the index specified ‘
n
’ is out of range of virtual triggers.
REBOOT [-noload]
Reboots the device.
-noload
= do not load BOOT job.