Ground and Shield Considerations
System Component
s
2
Vision HAWK Smart Camera Guide
2-17
Ground and Shield Considerations
Proper grounding is necessary for operator safety, noise reduction, and
the protection of equipment from voltage transients. Buildings, including
any steelwork, all circuits, and all junction boxes must be grounded
directly to an earth ground in compliance with local and national electrical
codes.
Ground Loops
Ground loops (signal degradation due to different ground potentials in
communicating devices) can be eliminated or minimized by ensuring that
both the host, imager, and their power supplies are connected to a
common earth ground.
An earth ground is provided through the cable shields and chassis of the imager.