MS-890 Industrial Automation Scanner User Manual
Serial Configuration Commands
Concatenating Configuration Commands
Commands can be concatenated (added together) in a single string or data block. For
example,
<K145
,1
><K220,
1
><K450,
1
><A>
enables
LRC
, sets
End of Read Cycle
mode
to
New Trigger
, enables
Narrow Margins
, and resets the data buffers (without saving the
changes for power-on).
Serial Command Status Request
To
ensure that any command was received and accepted, you can send the
Show Reader
Status
command:
<?>
.
The status of a specific serial command can be requested by entering the command followed
by a question mark. For example, send
<K142?>
to request the status of
Postamble
.
Entering Control Characters in Serial Commands
To enter control characters within a serial command, hold down the
Ctrl
key while typing the
desired character.
Example:
To enter a carriage return and line feed (
^M^J
), enter
<K141,1,CNTL-m CNTL-j>
Entering Special Characters in Embedded Menus
Control Characters
Control characters entered on the command line are displayed in the menu as mnemonic
characters, such as:
<CR><LF><NUL><NUL>
Press
SP
(the space bar) once, then enter the control character by holding down the
control key and simultaneously pressing the desired character. For example to define a
line feed, press
SP
, then
Control
and
J
simultaneously. It is displayed as
^J
on the command
line and as
<LF>
in the menu when the screen is refreshed.
To Define a Carriage Return as a Character
Press
SP
, then
CR
. It is displayed as
^M
on the command line and as
<CR>
in the menu
when the screen is refreshed.
To Define a Space as a Character
Press
SP
twice. It is displayed as a blank space in the menu when the screen is refreshed.
While it appears that nothing has been assigned, the hex value 20 will be sent during data
transmission.
To Select NUL as the Character
Press
SP
, then a
0
. It is displayed as
<NUL>
in the menu when the screen is refreshed.
Summary of Contents for MS-890
Page 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Page 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Page 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Page 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Page 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Page 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Page 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Page 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Page 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Page 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Page 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Page 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Page 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...