12-4
MS-890 Industrial Automation Scanner
User Manual
Read Rate
Read Rate
You can access
Read Rate
from the
Utilities
menu.
To start or end a read rate test, right-click
Read Rate
and select
Start
or
Stop
.
To change from percent read rate to decodes per second, first end the read rate by selecting
Stop
, then right-click select
Decodes/Sec
.
Read Rate by Serial Command
Enter Single Symbol Percent Test
Sending
<Cp>
instructs the scanner to transmit the percentage of decodes and any
scanned symbol data.
Enter Multisymbol Percent Test
Sending
<Cm>
instructs the scanner to transmit the percentage of scans decoded and
symbol data (if any) for multiple symbols.
Enter Single Symbol Read Rate Test
Sending
<C>
instructs the scanner to transmit the decodes per second and symbol data
(if any). The decode rate can vary dramatically due to the angle and location of the symbol
in relation to the scan line. This test is very useful in aligning and positioning the scanning
device during installation.
Enter Multisymbol Read Rate Test
Sending
<Cs>
instructs the scanner to transmit the decode rate and symbol data (if any)
for multiple symbols.
Enter Percent PDF Read Rate Test
Sending
<CPDF>
instructs the scanner to transmit the number of decodes per second on
the full PDF symbol. This test includes both capture and decode and translation time. Note
that the output format of the data is done as a running average of 750ms windows. This
means that you can remove the symbol from the view of the scanner and it will continue to
transmit some history of the symbol for a few outputs.
Enable PDF Information
Sending the
<a1>
check box will cause PDF417 symbology data to be prefaced with
information consisting of error correction level, number of rows, number of columns,
number of informative code words and the number of data characters.
This feature can be disabled by using the exit read rate command
<J>
.
Summary of Contents for MS-890
Page 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Page 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Page 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Page 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Page 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Page 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Page 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Page 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Page 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Page 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Page 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Page 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Page 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...