9-20
MS-890 Industrial Automation Scanner
User Manual
Calibration by Embedded Menu
Calibration Results in Embedded Menus
To access
Calibration Results
menu from within the
Calibration Setup
menu, type the
numeral
1
.
The
Calibration Results
menu shows the results of the calibration process for
Read
Rate
,
Gain
, and
Tracking
for both the first and second passes. Note that the first pass
has only one reading for each parameter.
Focus Positions
In the example above, the focus position selected from the first calibration pass (position
26) represents the optimal focus position for
Read Rate
,
Gain
, and
Tracking
. The second
“fine tune” pass commences 3 focus positions in from this and steps out until the read rate
drops off to zero.
Focal Range
The algorithm selects the best focus position (
SET
) as the midpoint between those positions
(
IN
and
OUT
) at which read rates drop off by no more than 6-2/3 percent of the maximum
read rate. For example, in the above menu, the read rate for focus position 24 is 73. Since
73 is more than 6-2/3% below the maximum read rate of 100% shown elsewhere, the
IN
range falls under the next focus position, 25. A mirrored calculation is performed to locate
the
OUT
focal range.
Press the enter key (
CR
) to return to the main calibration menu or
ESC
to leave the
Auto
Calibration Setup
menu entirely.
Summary of Contents for MS-890
Page 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Page 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Page 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Page 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Page 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Page 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Page 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Page 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Page 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Page 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Page 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Page 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Page 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...