MS-890 Industrial Automation Scanner
User Manual
5-3
Symbologies
Code 39
Code 39 Status
Check Character Status (Code 39)
Check Character Output
(Code 39)
Usage:
Code 39
is considered the standard for non-retail applications.
Definition:
An alphanumeric symbol with unique start/stop symbol patterns, composed
of 9 black and white elements per character, of which 3 are wide.
Serial Cmd:
<
K470,
status
,check character status,check character output,large intercharacter
gap,fixed symbol length status,symbol length,full ASCII set>
Default:
Enabled
Note
: This is the only symbol type enabled by default.
Options:
0 = Disabled
1 = Enabled
Serial Cmd:
<
K470,
status,
check character status
,check character output,large intercharacter
gap,fixed symbol length status,symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Check Character Output Status
, added to the symbol, provides additional
security.
Definition:
When enabled, the check character is read and sent along with the symbol
data. When disabled, symbol data is sent without the check character.
Note
: With
Check Character Output Status
and an
External
or
Serial
trigger
option enabled, an invalid check character calculation will cause a No
Read message
to be transmitted at the end of the read cycle.
Serial Cmd:
<
K470,
status,check character status
,
check character output
,
large intercharacter
gap,fixed symbol length status,symbol length,full ASCII set
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Summary of Contents for MS-890
Page 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Page 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Page 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Page 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Page 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Page 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Page 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Page 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Page 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Page 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Page 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Page 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Page 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...