MS-890 Industrial Automation Scanner
User Manual
6-17
I/O Parameters
EZ Button Modes
Disabled
When set to disabled, the associated button position will have no function associated with
it, and the position will be skipped over.
Read Rate
Read Rate will be initiated when the associated button position is selected. Read Rate will
perform decodes/second and is the same as sending a
<C>
from the terminal. To exit
Read Rate Mode quickly press and release the EZ Button.
Calibration
Calibration will be initiated when the associated button position is selected. To abort calibration
,
quickly press and release the EZ Button.
Save for Power-On
All scanner settings will be saved to non-volatile memory to be recalled on power-on
whenever the associated button position is selected. This is the same as sending a
<Z>
from the terminal.
Load New Master
Functions in the same way as new master pin input whenever the associated button
position is selected. The new master pin’s
Consecutive Decode
requirement holds true
for this function.
Bar Code Configuration
Enables Bar Code Configuration mode whenever the associated button position is
selected. When enabled, the scanner can accept configuration commands from symbols.
To disable, quickly press and release the EZ Button.
Usage:
Useful for performing multiple, repetitive tasks at the work site.
Definition:
Allows the user to program each of the EZ Button’s 3 positions from a selection
of 10 modes.
Serial Cmd:
<
K771,
single beep,two beeps,three beeps
>
Options:
Single Beep
Two Beeps
Three Beeps
0 = Disabled
0 = Disabled
0 = Disabled
1 = Read Rate
1 = Read Rate
1 = Read Rate
2 = Calibration
2 = Calibration
2 = Calibration
3 = Save for Power-On
3 = Save for Power-On
3 = Save for Power-On
5 = Load New Master
5 = Load New Master
5 = Load New Master
9 = Bar Code Configuration
9 = Bar Code Configuration
9 = Bar Code Configuration
Summary of Contents for MS-890
Page 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Page 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Page 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Page 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Page 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Page 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Page 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Page 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Page 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Page 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Page 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Page 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Page 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...