MS-890 Industrial Automation Scanner
User Manual
5-17
Symbologies
Supplemental Status (UPC/EAN)
Note
: Under no circumstances will supplemental symbol data be sent without a main symbol.
Note
:
If additional symbols—other than the main or supplemental—will be read in the
same read cycle,
Number of Symbols
should be set accordingly.
Separator Status (UPC/EAN)
Usage:
Reads
Supplementals
typically used in publications and documentation.
Definition:
A supplemental is a 2 or 5 digit symbol appended to the main symbol.
When set to
Enabled
or
Required
, the scanner reads supplemental symbol
data that has been appended to the standard UPC or EAN codes.
Serial Cmd:
<
K473,
UPC status,EAN status,
supplemental status
,separator status,
separator character,supplemental type>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
2 = Required
Disabled:
UPC Supplementals
will not be decoded.
Enabled:
When enabled, the scanner will try to decode a main and a supplemental.
However, if a supplemental is not decoded, at the end of the read cycle, the
main will be sent by itself. The UPC main and supplemental symbols are
considered to be one symbol and will be treated as such.
Required:
When set to
Required
and either the main or supplemental symbol is not
read, a single No Read condition results. The UPC main and supplemental
symbols are treated as one symbol.
For example, if
Supplementals
is set to
Required
,
Separator
is enabled,
and an asterisk is defined as the UPC separator character, then the data
will be displayed as: MAIN * SUPPLEMENTAL.
Usage:
Allows user to distinguish between the main and
Supplemental
symbols.
Definition:
Allows the user to insert a character between the standard UPC or UPC/EAN
symbol and the supplemental symbol when
Supplementals
is set to
Enabled
or
Required
.
Serial Cmd:
<
K473,
UPC status,EAN status,supplemental status,
separator status
,separator
character,supplemental type>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Summary of Contents for MS-890
Page 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Page 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Page 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Page 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Page 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Page 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Page 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Page 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Page 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Page 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Page 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Page 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Page 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...